Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
ΔV
O(LINE)
Line regulation
ΔV
REG1
vs (V
REG1
at 25°C, V
REGIN
=
5.5 V, I
REG1
= 20 mA), as V
REGIN
varies
from 5 V to 6 V, V
REG1
set to nominal
3.3 V setting
–1
1
%
I
SC
Regulator short-circuit current limit
V
REG1
= 0 V
47
80
mA
C
EXT
External capacitor REG1 to VSS
1
µF
(1)
Operation with V
BAT
up to 80 V is supported when the charge pump is not in operation. Whenever the charge pump is in operation (in
5.5 V or 11 V mode), the maximum voltage on V
BAT
should be reduced to ensure the voltage on CP1, CHG, and DSG does not exceed
their maximum specified voltage.
(2)
Specified by design
7.13 REG2 LDO
Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
REG2_1.8
Regulator voltage (nominal 1.8V setting)
V
REGIN
≥ 3.0 V, I
REG2
= 0 mA to 45 mA
1.6
1.84
2
V
V
REG2_2.5
Regulator voltage (nominal 2.5V setting)
V
REGIN
≥ 3.5 V, I
REG2
= 0 mA to 45 mA
2.25
2.55
2.75
V
V
REG2_3.0
Regulator voltage (nominal 3.0V setting)
V
REGIN
≥ 3.8 V, I
REG2
= 0 mA to 45 mA
2.7
3.06
3.3
V
V
REG2_3.3
Regulator voltage (nominal 3.3V setting)
V
REGIN
≥ 4.1 V, I
REG2
= 0 mA to 45 mA
3.0
3.38
3.6
V
V
REG2_5.0
Regulator voltage (nominal 5.0V setting)
V
REGIN
≥ 5.0 V, I
REG2
= 0 mA to 45 mA
4.5
5.23
5.5
V
ΔV
O(TEMP)
Regulator output over temperature
ΔV
REG2
vs (V
REG2
at 25°C, I
REG2
= 20
mA, V
REGIN
= 5.5 V, V
REG2
set to
nominal 3.3 V setting)
±0.25
%
ΔV
O(LINE)
Line regulation
ΔV
REG2
vs (V
REG2
at 25°C, V
REGIN
=
5.5 V, I
REG2
= 20 mA), as V
REGIN
varies
from 5 V to 6 V, V
REG2
set to nominal
3.3 V setting
–1
1
%
I
SC
Regulator short-circuit current limit
V
REG2
= 0 V
47
80
mA
C
EXT
External capacitor REG2 to VSS
1
µF
(1)
Operation with V
BAT
up to 80 V is supported when the charge pump is not in operation. Whenever the charge pump is in operation (in
5.5 V or 11 V mode), the maximum voltage on V
BAT
should be reduced to ensure the voltage on CP1, CHG, and DSG does not exceed
their maximum specified voltage.
(2)
Specified by design
7.14 Voltage References
Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VOLTAGE REFERENCE 1
V
(REF1)
T
A
= 25°C
1.210
1.212
1.214
V
V
(REF1DRIFT)
Internal reference voltage drift
T
A
= -10°C to 60°C
±10
PPM/°C
V
(REF1DRIFT)
Internal reference voltage drift
T
A
= -40°C to 85°C
±10
PPM/°C
VOLTAGE REFERENCE 2
V
(REF2)
T
A
= 25°C
1.23
1.24
1.25
V
V
(REF2DRIFT)
Internal reference voltage drift
T
A
= -10°C to 60°C
±20
PPM/°C
V
(REF2DRIFT)
Internal reference voltage drift
T
A
= -40°C to 85°C
±50
PPM/°C
(1)
Operation with V
BAT
up to 80 V is supported when the charge pump is not in operation. Whenever the charge pump is in operation (in
5.5 V or 11 V mode), the maximum voltage on V
BAT
should be reduced to ensure the voltage on CP1, CHG, and DSG does not exceed
their maximum specified voltage.
SLUSE91A – SEPTEMBER 2020 – REVISED FEBRUARY 2021
14
Copyright © 2021 Texas Instruments Incorporated
Product Folder Links: