![Texas Instruments BQ769142 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/texas-instruments/bq769142/bq769142_manual_1095400012.webp)
7.7 LD Pin
Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
I
(PULLUP)
Internal pullup current from BAT pin to LD
pin, used for load detect functionality
V
BAT
≥ 4.7 V, V
LD
= VSS
35
100
172
µA
R
PD
Internal pulldown resistance on LD pin in
SHUTDOWN mode
V
BAT
≥ 4.7 V
80
kΩ
(1)
Operation with V
BAT
up to 80 V is supported when the charge pump is not in operation. Whenever the charge pump is in operation (in
5.5 V or 11 V mode), the maximum voltage on V
BAT
should be reduced to ensure the voltage on CP1, CHG, and DSG does not exceed
their maximum specified voltage.
7.8 Precharge (PCHG) and Predischarge (PDSG) FET Drive
Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
(PCHG_ON)
Output voltage, PCHG on
max(V
PACK
, V
BAT)
- V
PCHG
, V
PACK
≥ 8 V,
V
BAT
≥ 4.7 V
7.5
8.4
9.7
V
V
(PCHG_ON)
Output voltage, PCHG on
V
PACK
- V
PCHG
, 4.7 V ≤ V
PACK
< 8 V, V
BAT
≥ 4.7 V, V
PACK
> V
BAT
V
PACK
–
0.5 V
V
PACK
V
V
(PDSG_ON)
Output voltage, PDSG on
max(V
LD
, V
BAT
) - V
PDSG
, V
BAT
≥ 8 V
7.47
8.4
9.7
V
V
(PDSG_ON)
Output voltage, PDSG on
V
BAT
- V
PDSG
, 4.7 V ≤ V
BAT
< 8 V, V
BAT
≥
V
LD
V
BAT
–
0.5 V
V
BAT
V
I
(PULLDOWN)
Current sink capability, PCHG and
PDSG
PCHG and PDSG enabled, V
BAT
= 59.2 V
30
µA
(1)
Operation with V
BAT
up to 80 V is supported when the charge pump is not in operation. Whenever the charge pump is in operation (in
5.5 V or 11 V mode), the maximum voltage on V
BAT
should be reduced to ensure the voltage on CP1, CHG, and DSG does not exceed
their maximum specified voltage.
7.9 FUSE Pin Functionality
Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
(OH)
Output voltage high (when driving fuse)
V
BAT
≥ 8 V, C
L
= 1 nF, 5 kΩ load.
6
7
9
V
V
(OH)
Output voltage high (when driving fuse)
4.7 V ≤ V
BAT
< 8 V, C
L
= 1 nF, 5 kΩ load.
V
BAT
–
1.75
V
V
(IH)
High-level input (for fuse detection)
Current into device pin must be limited to
maximum 2 mA
2
12
V
V
(IL)
Low-level input (for fuse detection)
0.7
V
t
(RISE)
Output rise time (when driving fuse)
V
BAT
≥ 8 V, C
L
= 1 nF, R
LOAD
= 5 kΩ,
V
(OH)
= 10% to 90% of final settled
voltage
0.5
µs
(1)
Operation with V
BAT
up to 80 V is supported when the charge pump is not in operation. Whenever the charge pump is in operation (in
5.5 V or 11 V mode), the maximum voltage on V
BAT
should be reduced to ensure the voltage on CP1, CHG, and DSG does not exceed
their maximum specified voltage.
7.10 REG18 LDO
Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
C
REG18
External capacitor, REG18 to VSS
1.8
2.2
22
µF
V
REG18
Regulator voltage
1.6
1.8
2
V
SLUSE91A – SEPTEMBER 2020 – REVISED FEBRUARY 2021
12
Copyright © 2021 Texas Instruments Incorporated
Product Folder Links:
Содержание BQ769142