Control()/CONTROL_STATUS(): 0x00 and 0x01
55
SLUUBE8 – September 2018
Copyright © 2018, Texas Instruments Incorporated
Data Commands
4.1.13
IGNORE_SELFDSG_EN: 0x0020
This MAC subcommand toggles the value of
ManufacturingStatus()[IGNORE_SD_EN]
.
4.1.14 PIN_CONTROL_EN: 0x0022
This command toggles control of the ALERT pin via the
ALERT_SET
and
ALERT_RESET
commands. It
is indicated by
ManufacturingStatus[PCTL_EN]
. Care must be taken when using this function when a true
Alert might occur. Use may cause the system to miss the Alert.
4.1.15 CAL_TOGGLE: 0x002D
Toggles the
OperationStatus()[CALMD]
flag
4.1.16 SEAL: 0x0030
This instructs the fuel gauge to transition from the UNSEALED state to the SEALED state. The fuel gauge
must always be set to the SEALED state for use in end-equipment.
Sending the SEAL command will set
Operation Config A [DEFAULTSEAL]
, which will cause the gauge
to automatically reseal unless the
DEFAULTSEAL
bit is cleared.
4.1.17 EOS_START_LEARN: 0x0039
This MAC subcommand instructs the bq34210-Q1 device to begin a learning phase.
4.1.18 EOS_ABORT_LEARN: 0x003A
This MAC subcommand instructs the bq34210-Q1 device to stop a learning phase.
4.1.19 EOS_RCELL_RRATE_LEARN: 0x003B
This MAC subcommand instructs the bq34210-Q1 device to initiate an
Initial Rcell
and an
Initial RRate
measurement.
4.1.20 EOS_WARN_CLEAR: 0x003C
This MAC subcommand instructs the bq34210-Q1 device to clear the EOS warning bits (this includes
[DRDWARN]
,
[RSDWARN]
, and
[RSDLWARN]
).
4.1.21 EOS_INITIAL_RCELL: 0x003E
This MAC subcommand is used to read the stored
Initial_Rcell
measurement or to overwrite the value
with a previously measured value.
4.1.22 EOS_INITIAL_RRATE: 0x003F
This MAC subcommand is used to read the stored
Initial_RRate
measurement or to overwrite the value
with a previously measured value.
4.1.23 RESET: 0x0041
This instructs the fuel gauge to perform a full reset.
NOTE:
This subcommand is available only when the fuel gauge is UNSEALED, and should be used
only
while in CONFIG UPDATE mode.
4.1.24 ACCUM_RESET: 0x004B
This command resets the accumulated charge registers.