Additional Data Memory Parameter Descriptions
47
SLUUBE8 – September 2018
Copyright © 2018, Texas Instruments Incorporated
Functional Description
2.9.52 Sleep Voltage Time
During SLEEP mode, temperature and voltage measurements will be taken in
Sleep Voltage Time
intervals. The default setting is 20 s.
2.9.53 Sleep Current Time
During SLEEP mode, current will be measured in
Sleep Current Time
intervals. The default value is 20 s.
2.9.54 Dsg Current Threshold (Discharge Detection Threshold)
The bq34210-Q1 device enters DISCHARGE mode from RELAXATION mode or CHARGE mode if
Current()
< (–)
Dsg Current Threshold
.
2.9.55 Chg Current Threshold (Charge Detection Threshold)
The bq34210-Q1 device enters CHARGE mode from RELAXATION mode or DISCHARGE mode if
Current()
>
Chg Current Threshold
.
2.9.56 Quit Current
The bq34210-Q1 device enters RELAXATION mode from CHARGE mode if
Current()
goes below
Quit Current
for
Charge Relax Time
. The device enters RELAXATION mode from DISCHARGE mode if
Current()
goes above
(–)Quit Current
for
Discharge Relax Time
.
2.9.57 Discharge Relax Time
The bq34210-Q1 device enters RELAXATION mode from DISCHARGE mode if
Current()
goes above
(–)Quit Current
for at least
Discharge Relax Time
.
NOTE:
To optimize power consumption, it is recommended to set
Discharge Relax Time
to 0 so
the device enters RELAXATION mode immediately when
Current()
rises above
(–)Quit Current
.
2.9.58 Charge Relax Time
The bq34210-Q1 device enters RELAXATION mode from CHARGE mode if
Current()
goes below
Quit Current
for at least
Charge Relax Time
.
2.9.59 Quit Relax Time
The
Quit Relax Time
is the delay time to exit RELAXATION. If current is greater than
Chg Current
Threshold
or less than
Dsg Current Threshold
and this condition is maintained for
Quit Relax Time
,
then exiting RELAXATION is permitted. This is useful in applications with low duty cycle dynamic loads.
2.9.60 OT Charge
The bq34210-Q1 device sets the
[OTC]
flag in
BatteryStatus()
if the pack
Temperature()
is equal to or
higher than the
Over Temp Chg
threshold.
2.9.60.1 OT Charge Time
If the
[OTC]
condition exists for a time that exceeds the
OT Chg Time
period, the bq34210-Q1 device
goes into an overtemperature charge condition. This function is disabled if
OT Chg Time
is set to 0.
In an overtemperature charge condition, the
ChargingVoltage()
and
ChargingCurrent()
are set to 0, and
the
[OTC]
bit is set in the
BatteryStatus()
register.