Control()/CONTROL_STATUS(): 0x00 and 0x01
54
SLUUBE8 – September 2018
Copyright © 2018, Texas Instruments Incorporated
Data Commands
RSVD = Reserved
BATT_ID0 = Battery Identification Setting. Battery identification settings for different chemistries, used to select one of
two chemistry IDs.
0 = CEDV Profile 1
1 = CEDV Profile 2
One of these CEDV profiles is loaded it initial power. The host can modify the memory parameters to fit
the particular requirement of the system battery.
4.1.2 DEVICE_NUMBER: 0x0001
This command instructs the fuel gauge to return
Device Type
0x0210 to
MACData()
.
4.1.3 FW_VERSION: 0x0002
This command instructs the fuel gauge to return the firmware revision on
MACData()
in the following
format:
ddDDvvVVbbBBTTzzZZRREE, where
ddDD: Device Number
vvVV: Version
bbBB: Build number
ttTT: Firmware type.
4.1.4
BOARD_OFFSET: 0x0009
This command instructs the fuel gauge to measure and store the board offset value.
4.1.5
CC_OFFSET: 0x000A
This command instructs the fuel gauge to measure the internal CC offset value.
4.1.6
CC_OFFSET_SAVE: 0x000B
This command instructs the fuel gauge to store the internal CC offset value.
4.1.7 SET_PROFILE_1: 0x0015
This command selects CEDV Profile 1.
4.1.8 SET_PROFILE_2: 0x0016
This command selects CEDV Profile 2.
4.1.9 SHUTDOWN_ENABLE: 0x001B
This command enables entry into SHUTDOWN mode with the SHUTDOWN command.
4.1.10 SHUTDOWN: 0x001C
This command puts the device into low power SHUTDOWN mode. Exit is done with a power cycle or
through the ALERT pin.
4.1.11 ACCUM_DSG_EN: 0x001E
This MAC subcommand toggles the value of
ManufacturingStatus()[ACDSG_EN]
.
4.1.12 ACCUM_CHG_EN: 0x001F
This MAC subcommand toggles the value of
ManufacturingStatus()[ACCHG_EN]
.