AnalogCount(): 0x79
66
SLUUBE8 – September 2018
Copyright © 2018, Texas Instruments Incorporated
Data Commands
RCELLR =
Rcell
Reduction Alert
This bit is set = 1 if the bq34210-Q1 EOS Determination function detects a value of Rcell that is
more than 2% below the previous value of
Rcell
. This signal is cleared when the register is read or if
a new learning phase begins.
1 = A reduction in
Rcell
was detected.
0 = A reduction in
Rcell
was not detected.
IRRCOMP =
Initial RRate
Calculation Complete
This bit is set = 1 if the bq34210-Q1 EOS Determination function has completed the required
learning phases to calculate a value of
Initial RRate
. This bit is reset when a new
Initial RRate
calculation is triggered until the new calculation is complete. This bit can be written by the host
through loading data flash if the host chooses to initialize the device with previously calculated
Initial
RRate
data and not trigger a new
Initial RRate
calculation.
1 =
Initial RRate
was obtained.
0 =
Initial RRate
was not obtained.
IRCOMP =
Initial Rcell
Calculation Complete
This bit is set = 1 if the bq34210-Q1 EOS Determination function has completed the required
learning phases to calculate a value of
Initial Rcell
. This bit is reset when a new
Initial Rcell
calculation is triggered until the new calculation is complete. This bit can be written by the host
through loading data flash if the host chooses to initialize the device with previously calculated
Initial
Rcell
data and not trigger a new
Initial Rcell
calculation.
1 =
Initial Rcell
was obtained.
0 =
Initial Rcell
was not obtained.
4.33 AnalogCount(): 0x79
This read-only function returns the analog counter. The value is incremented every time the analog data
for calibration was updated.
4.34 RawCurrent(): 0x7A and 0x7B
This read-only function returns the raw data from the coulomb counter.
4.35 RawVoltage(): 0x7C and 0x7D
This read-only function returns the raw data from the cell voltage reading.
4.36 RawIntTemp(): 0x7E and 0x7F
This read-only function returns the raw data from the internal temperature measurement.
4.37 RawExtTemp(): 0x80 and 0x81