8 Specifications
8.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)
MIN
MAX
UNIT
Input voltage
IN
wrt GND
–0.3
20
V
PMID, VINLS
wrt GND
–0.3
7.7
V
CD, SDA, SCL, ILIM, ISET, IPRETERM, LSCTRL,
INT, RESET, TS
wrt GND
–0.3
5.5
V
Output voltage
SYS
3.6
V
Input current
IN
400
mA
Sink current
INT
10
mA
Sink/Source Current
RESET
10
mA
Output Voltage Continuos
SW
–0.7
7.7
V
Output Current Continuous
SW
400
mA
SYS, BAT
300
mA
Current
LS/LDO
150
mA
BAT Operating Voltage
VBAT, MR,
6.6
V
Junction Temperature
–40
125
°C
Storage Temperature, T
stg
–55
150
°C
(1)
Stresses beyond those listed under
Absolute Maximum Ratings
may cause permanent damage to the device. These are stress
ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under
Recommended Operating Conditions
. Exposure to absolute-maximum-rated conditions for extended periods may affect device
reliability.
8.2 ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001
±2000
V
Charged device model (CDM), per JEDEC specification JESD22-
C101
±500
(1)
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
8.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN
NOM
MAX
UNIT
V
IN
IN voltage range
3.4
5
20
V
IN operating voltage range, recommended
3.4
5
5.5
V
(BAT)
V
(BAT)
operating voltage range
5.5
V
V
(VINLS)
VINLS voltage range for Load Switch
0.8
5.5
V
V
(VINLS)
VINLS voltage range for LDO
2.2
5.5
V
I
IN
Input Current, IN input
400
mA
I
(SW)
Output Current from SW, DC
300
mA
I
(PMID)
Output Current from PMID, DC
300
mA
ILS/LDO
Output Current from LS/LDO
100
mA
I
(BAT)
, I
(SYS)
Charging and discharging using internal battery FET
300
mA
T
J
Operating junction temperature range
–40
125
°C
(1)
Any voltage greater than shown should be a transient event.
(2)
These inputs will support 6.6 V for less than 10% of the lifetime at V
(BAT)
or VIN, with a reduced current and/or performance.
SLUSDI4A – OCTOBER 2018 – REVISED APRIL 2021
6
Copyright © 2022 Texas Instruments Incorporated
Product Folder Links: