Table 9-17. Battery Voltage Control Register (continued)
Bit
Field
Type
Reset
Description
VBREG Bits: Use VBREG bits to set the battery regulation threshold. The V
BATREG
is calculated using the following equation: V
BATREG
= 3.6
V + V
BREG
CODE x 10 mV. The charge voltage range is from 3.6 V to 4.65 V. If a value greater than 4.65 V is written, the setting goes to
4.65 V.
SLUSDI4A – OCTOBER 2018 – REVISED APRIL 2021
40
Copyright © 2022 Texas Instruments Incorporated
Product Folder Links: