9.6.7 SYS VOUT Control Register
Memory location 0x06h, Reset State: 1010 1010 (BQ25120F3A)
Figure 9-17. SYS VOUT Control Register
7 (MSB)
6
5
4
3
2
1
0 (LSB)
1
0
1
0
1
0
1
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 9-18. SYS VOUT Control Register
Bit
Field
Type
Reset
Description
B7 (MSB) EN_SYS_OUT
R/W
1
0 – Disable SW
1 – Enable SW
(When disabled, output is pulled low)
B6
SYS_SEL1
R/W
0
00 – 1.1 V and 1.2 V selection
01 – 1.3 V through 2.8 V selection
10 – 1.5V through 2.75 V selection
11 – 1.8 V through 3.3 V selection
B5
SYS_SEL0
R/W
1
B4
SYS_VOUT_3
R/W
0
OUT Voltage: 800 mV step if SYS_SEL is 01 or 11
B3
SYS_VOUT_2
R/W
1
OUT Voltage: 400 mV step if SYS_SEL is 01 or 11
B2
SYS_VOUT_1
R/W
0
OUT Voltage: 200 mV step if SYS_SEL is 01 or 11
B1
SYS_VOUT_0
R/W
1
OUT Voltage: 100 mV step if SYS_SEL is 01 or 11
B0 (LSB)
0
SW_VOUT Bits: Use SYS_SEL and SYS_VOUT bits to set the output on SYS. The SYS voltage is calculated using the following equation:
See table below for all VOUT values that can be programmed through SYS_SEL and SYS_VOUT.
If SYS_SEL = 01, then SYS = 1.30 V + SYS_VOUTCODE x 100 mV.
If SYS_SEL = 11, then SYS = 1.80 V + SYS_VOUTCODE x 100 mV.
Table 9-19. SYS_SEL Codes
SYS_SEL
SYS_VOUT
TYP
UNIT
00
0000
1.1
V
00
0001
1.2
V
00
0010
1.25
V
00
0011
1.333
V
00
0100
1.417
V
00
0101
1.5
V
00
0110
1.583
V
00
0111
1.667
V
00
1000
1.75
V
00
1001
1.833
V
00
1010
1.917
V
00
1011
2
V
00
1100
2.083
V
00
1101
2.167
V
00
1110
2.25
V
00
1111
2.333
V
01
0000
1.3
V
01
0001
1.4
V
01
0010
1.5
V
01
0011
1.6
V
SLUSDI4A – OCTOBER 2018 – REVISED APRIL 2021
Copyright © 2022 Texas Instruments Incorporated
41
Product Folder Links: