5 Description (continued)
The battery is charged using a standard Li-Ion charge profile with three phases: precharge, constant current
and constant voltage. A voltage-based battery pack thermistor monitoring input (TS) is included that monitors
battery temperature and automatically changes charge parameters to prevent the battery from charging outside
of its safe temperature range. The charger is optimized for 5-V USB input, with 20-V tolerance to withstand line
transients. The buck converter is run from the input or battery. When in battery only mode, the device can run
from a battery up to 4.65 V.
A configurable load switch allows system optimization by disconnecting infrequently used devices. The manual
reset with timer allows multiple different configuration options for wake are reset optimization. A simple voltage
based monitor provides battery level information to the host in 2% increments from 60% to 100% of the
programmed V
(BATREG)
.
6 Device Comparison Table
PART
NUMBER
Default
VINDPM
DEFAULT
SYS OUTPUT
DEFAULT
LDO OUTPUT
DEFAULT
VBATREG
DEFAULT
CHARGE
CURRENT
DEFAULT
TERMINATION
CURRENT
VDPPM
WATCHDOG
BQ25120F3A
Enabled
1.8 V
1.8 V (LDO)
4.35 V
40 mA
10 mA
Enabled
Disabled
BQ25120A
Enabled
1.8 V
Load Switch
4.2 V
10 mA
2 mA
Enabled
Enabled
BQ25121A
Enabled
2.5 V
Load Switch
4.2 V
10 mA
2 mA
Enabled
Disabled
BQ25122
Enabled
1.2 V
Load Switch
4.2 V
11 mA
0.5 mA
Enabled
Enabled
BQ25125
Disabled
1.8 V
1.8 V (LDO)
4.2 V
10 mA
2 mA
Disabled
Enabled
SLUSDI4A – OCTOBER 2018 – REVISED APRIL 2021
Copyright © 2022 Texas Instruments Incorporated
3