TCP201 User Manual Issue 1.4
Page 33 of 35
6 Installation of IndustryPacks
Before installing an IndustryPack, be sure that the power supply for the TCP201 is turned off.
The component is an Electrostatic Sensitive Device (ESD). Use an anti-static mat connected to
a wristband when handling or installing the components.
Installing IndustryPacks on the TCP201 is done by simply snapping them into one of the four IP slots.
The connectors are keyed, so the IndustryPack can only be installed correctly.
After an IP has been installed it can be secured on the carrier board. This is normally necessary only
in high vibration or shock environments.
Screws and spacers are required to fix a single IP on the TCP201. They can be ordered from TEWS
TECHNOLOGIES (Part number: TIPxxx-HK).
All IPs mate with 50-pin SCSI-2 type connectors (AMP 787395-5) for their I/O. The PCB and front
panel labeling indicates, which connector is associated with the according IP slot. Pin 1 for each cable
is identified by the mark on the connector or a square solder pad.
Figure 6-1 : I/O Pin Order