TAMC900 User Manual Issue 2.0.1
Page 60 of 71
14 Signal Conditioning Adapter (SiCA)
The SiCA holds the connector for the analog inputs, the connectors for the clock and trigger inputs and the
analog signal conditioning for the TAMC900. Depending on customer needs, the form and function of the
SiCA can vary. For more information please refer to the corresponding SiCA User Manual.
The SiCA is powered from the TAMC900 with +6 Volts from a switched power supply. Any other voltages
needed must be generated on the SiCA.
A 120 pin high speed connector from Samtec (QSE-060-01-L-D-A) is used on the TAMC900 to interface with
the SiCA. The pin assignment of this connector can be found in the chapter “I/O Connector”.
14.1
Connector and Standoff Positions
Five mounting positions for Standoffs are provided by the TAMC900 to secure the SiCA on the TAMC900.
Depending on the size of the SiCA, all or only a subset of these can be used to secure the SiCA on the
TAMC900. See figure below for the exact position.
27,80 mm
157,20 mm
37,80 mm
71,50 mm
157,20 mm
5,83 mm
7,20 mm
66,40 mm
46,22 mm
67,73 mm
11,13 mm
59,10 mm
Figure 14-1: TAMC900 Connector and Standoff Positions