Common Errors
|
4-7
Engineered to Endure
External Mute
When the IBUC operates as a single thread IBUC, Pin N of the M&C interface
connector functions as an external mute. If it is not connected (left open), then
transmission is not muted. When Pin N is connected to Pin F (chassis ground),
transmission is muted.
To re-enable transmission, remove the Pin N connection to Pin F. Transmission will
now resume.For more information about the M&C interface connector, see
.
Common Errors
LED is Red
A red LED indicates only that a fault (or alarm) has occurred and does not necessarily
indicate that transmission has stopped. A flashing red light indicates a minor alarm and
a solid red light indicates a major alarm. You can communicate with the IBUC to
determine what is causing the fault, and then clear the fault condition.
1. Establish a connection with the Cyber Hardened IBUC
2
, IBUC
2e
, IBUC
2
G
,
IBUC
R
or IBUC
G
, described in
or by the steps provided in
2. To determine current alarm status, the user should query the IBUC via
command, described on
When the fault is cleared, the LED should be flashing green.
No Power to the Cyber Hardened IBUC
2
, IBUC
2e
, IBUC
2
G
, IBUC
R
or
IBU
C
G
If the Power LED is off or not turning on at all, the IBUC is probably not receiving
power.
Restore power to the IBUC by
• If the IBUC is powered by the modem, verifying that the modem is working
properly.
• Checking that the modem is receiving power (that is, the modem power cord is
plugged in) and that DC power to the IBUC is enabled.
• Checking that all cable connections are solid.
• Checking that the power supply is functioning or that AC mains has the proper
voltage.
Содержание IBUC 2
Страница 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Страница 8: ...vi Engineered to Endure ...
Страница 12: ...4 Engineered to Endure ...
Страница 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Страница 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Страница 72: ...3 24 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Installation Engineered to Endure ...
Страница 102: ...6 10 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Troubleshooting Engineered to Endure ...
Страница 106: ...A 4 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Part Numbering Schema Engineered to Endure ...
Страница 128: ...B 22 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Embedded Web Pages Engineered to Endure ...
Страница 179: ...Reference Drawings D 3 Engineered to Endure Figure D 2 Fabrication Drawing FBD 21984 XXXX Rev B page 1 of 2 ...
Страница 181: ...Reference Drawings D 5 Engineered to Endure Figure D 4 Fabrication Drawing FBD 20606 XXXX Rev A ...
Страница 196: ...I n d e x 4 ...