![Terrasat IBUC 2 Скачать руководство пользователя страница 116](http://html.mh-extra.com/html/terrasat/ibuc-2/ibuc-2_operation-manual_1089881116.webp)
B-10
|
Cyber Hardened IBUC
2
,
IBUC
2e
,
IBUC
2
G
,
IBUC
R
,
IBUC
G
Operations Manual: Embedded Web Pages
Engineered to Endure
• Temperature (Internal)
Indicates that the internal temperature of the IBUC exceeds 85° C.
Note:
If the High Temperature Shutdown alarm has been enabled and the internal
temperature of the IBUC exceeds 85° C, the IBUC will shut down automatically
• 10 MHz Source
Indicates whether the source of the 10 MHz reference signal is internal or external.
Note:
For IBUCs operating with only an external 10 MHz reference signal, this field is
labelled “10 MHz Detector” and the options include:
•
OK (indicates that the 10 MHz signal is functioning properly)
•
Low (indicates that the 10 MHz signal is low or missing)
• PLDRO Lock
Indicates whether the phase-locked dielectric resonator oscillator (PLDRO)
frequency is locked (or stable). When the PLDRO is out-of-lock, this alarm causes
the muting of the amplifier and automatically shuts down the IBUC. Options
include:
•
OK (indicates that the PLDRO is locked and functioning properly)
•
Major
Note:
This alarm is always a major alarm and is not available for user configuration.
• AGC Range
Indicates that the automatic gain control function is unable to maintain the gain
level. Options include:
•
OK
•
Major
This alarm occurs whenever the internal AGC gain is out of range and can no
longer maintain the desired Tx Output level
•
N/A
• ALC Range
Indicates that the Tx Output level is being kept constant by the automatic level
control (ALC) function. Options include:
•
OK
•
Major
This alarm occurs whenever the internal ALC gain is out of range and can no
longer maintain the desired Tx Output level
•
N/A
Note:
Both ALC Range and ACG Range alarms are always a major and are not available
for user configuration.
Содержание IBUC 2
Страница 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Страница 8: ...vi Engineered to Endure ...
Страница 12: ...4 Engineered to Endure ...
Страница 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Страница 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Страница 72: ...3 24 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Installation Engineered to Endure ...
Страница 102: ...6 10 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Troubleshooting Engineered to Endure ...
Страница 106: ...A 4 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Part Numbering Schema Engineered to Endure ...
Страница 128: ...B 22 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Embedded Web Pages Engineered to Endure ...
Страница 179: ...Reference Drawings D 3 Engineered to Endure Figure D 2 Fabrication Drawing FBD 21984 XXXX Rev B page 1 of 2 ...
Страница 181: ...Reference Drawings D 5 Engineered to Endure Figure D 4 Fabrication Drawing FBD 20606 XXXX Rev A ...
Страница 196: ...I n d e x 4 ...