![Terrasat IBUC 2 Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/terrasat/ibuc-2/ibuc-2_operation-manual_1089881089.webp)
Power Measurement
|
5-7
Engineered to Endure
• TERRASAT-MIB
• TERRASAT-SMI-MIB
• SNMP-FRAMEWORK-MIB
• SNMP-MPD-MIB
• SNMP-USER-BASED-SM-MIB
• SNMP-VIEW-BASED-ACM-MIB
• SNMP-TARGET-MIB
• SNMP-NOTIFICATION-MIB
Embedded Web Pages
Current IBUC configuration and status information also can be accessed via the
Embedded Web Pages. Although this method does not provide all of the
administrative privileges, such as user creation and deletion, it is the most intuitive for
overall IBUC management.
To access to Embedded Web Pages, open any Web browser and type the IP address of
the IBUC. A login page then appears. After login, the user will have a choice of eight
Web pages with IBUC status, control, alarm information and live charts. Individual
pages are displayed from the selection of the three main drop-down menus.
For more information about the options available on each Web page, see
Power Measurement
The Cyber Hardened IBUC
2
, IBUC
2e
, IBUC
2
G
, IBUC
R
and IBUC
G
are capable
of accurately reading the input and output power for a single carrier in either
continuous signal mode (CSM) or in burst mode. The dynamic range for input power
is from -55 dBm to -20 dBm and for output power the dynamic range is from rated
power to 20 dB below rated power. Each unit is loaded with a detector calibration
lookup table that compensates for detector variations in frequency, power level, and
temperature. The reported power level is then based on the user
-
requested frequency
and the internally monitored temperature and power level. If multiple carriers are
present, the composite transmit power level is read but accuracy is dependent upon the
actual carrier frequencies, levels, and modulation being used.
The power measurement occurs in the following two ways:
1. Burst Mode
In burst power measurement mode it is assumed that, in normal operation, a
transmit carrier may or not be present due to the nature of burst mode operation.
Содержание IBUC 2
Страница 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Страница 8: ...vi Engineered to Endure ...
Страница 12: ...4 Engineered to Endure ...
Страница 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Страница 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Страница 72: ...3 24 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Installation Engineered to Endure ...
Страница 102: ...6 10 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Troubleshooting Engineered to Endure ...
Страница 106: ...A 4 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Part Numbering Schema Engineered to Endure ...
Страница 128: ...B 22 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Embedded Web Pages Engineered to Endure ...
Страница 179: ...Reference Drawings D 3 Engineered to Endure Figure D 2 Fabrication Drawing FBD 21984 XXXX Rev B page 1 of 2 ...
Страница 181: ...Reference Drawings D 5 Engineered to Endure Figure D 4 Fabrication Drawing FBD 20606 XXXX Rev A ...
Страница 196: ...I n d e x 4 ...