Operations Manual: Installation
Engineered to Endure
J3 – DC Power
DC Power can be supplied to the IBUC through a 6
-
pin circular
socket connector. Pin assignments are listed in
Note:
The IBUC is factory configured for floating supply. J3 is internally connected and has
no VDC connection to Common.
Note:
The operating voltage is integrated into the model number of each IBUC. For more
information about the model number of your particular model IBUC, see
J3 – AC Power
AC Power is supplied to the through a 3
-
pin plus ground connector.
The connector is configured as described in
.
Note:
For high-power IBUC models such as IBUC G shown in
,
military grade Hirose connector is used.
Table 3.5
Pin Assignments for DC Power Connector J3
Pin
Function
A
VDC –
B
VDC –
C
VDC –
D
VDC +
E
VDC +
F
VDC +
Table 3.6
Pin Assignments for AC Power Connector J3
Pin
Function
1
N/C
2
Neutral
3
Line
4
Ground
!
CAUTION
For some coutries 220V
rms
is provided via Line-Line bus. If this is your
setup, connect one of the Line leads to the Line Pin of the IBUC connector,
and the other Line lead to the Neutral Pin of the connector.
In the case that 110V
rms
is needed, or 220V
rms
is provided via Line-Neutral
bus connect power leads to their matching connector pins.
Содержание IBUC 2
Страница 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Страница 8: ...vi Engineered to Endure ...
Страница 12: ...4 Engineered to Endure ...
Страница 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Страница 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Страница 72: ...3 24 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Installation Engineered to Endure ...
Страница 102: ...6 10 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Troubleshooting Engineered to Endure ...
Страница 106: ...A 4 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Part Numbering Schema Engineered to Endure ...
Страница 128: ...B 22 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Embedded Web Pages Engineered to Endure ...
Страница 179: ...Reference Drawings D 3 Engineered to Endure Figure D 2 Fabrication Drawing FBD 21984 XXXX Rev B page 1 of 2 ...
Страница 181: ...Reference Drawings D 5 Engineered to Endure Figure D 4 Fabrication Drawing FBD 20606 XXXX Rev A ...
Страница 196: ...I n d e x 4 ...