Operations Manual: Monitor and Control Features
Engineered to Endure
Note:
Your computer should have a static IP address on the same subnet as the IBUC. Using
a suitable cable, connect the computer to the J2 connector on the IBUC.
Determining the IP Address of Your IBUC
Due to the lack of support of DHCP, the IBUC IP address will not change after
configuration. In the event that such IP address is not known by the user, it is
recommended the usage of Wireshark® network packet analyzer for IP discovery.
SSHv2
SSHv2 enables you to connect to another computer by using a SSHv2 client from the
host PC. The default port for SSHv2 is 22. Characters are echoed back to the user. The
response is terminated with ‘
IBUC>’
. To initiate a session,
1. Activate a SSHv2 client program from the host computer such as PuTTY.
2. Configure SSHv2 Session with SSH port and IP address. Connect to the IBUC
unit.
3. At the “IBUC Login” prompt enter the username. A default banner will be
displayed followed by the “Password” prompt.
4. Enter the previously defined password. After this step, the user should see the
“IBUC>” prompt.
You can now use the ASCII commands to configure and monitor the IBUC. For more
Appendix C, ASCII Command/Response Structure
Note:
The Default administrator username/password for a new system is admin/admin. Upon
logging in, the administrator should create a new username/password via command
, described on
. After a successful creation of the new user, the system
administrator should logout from the Terrasat default username, login to the newly
created user and delete the Terrasat username via command
.
Note:
One might change the current username password via
detail on
!
CAUTION
D
o not delete
the default username before creating your new personalized
username.
D
o not delete
an IBUC user while logged into it.
Содержание IBUC 2
Страница 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Страница 8: ...vi Engineered to Endure ...
Страница 12: ...4 Engineered to Endure ...
Страница 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Страница 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Страница 72: ...3 24 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Installation Engineered to Endure ...
Страница 102: ...6 10 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Troubleshooting Engineered to Endure ...
Страница 106: ...A 4 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Part Numbering Schema Engineered to Endure ...
Страница 128: ...B 22 Cyber Hardened IBUC 2 IBUC 2e IBUC 2G IBUC R IBUC G Operations Manual Embedded Web Pages Engineered to Endure ...
Страница 179: ...Reference Drawings D 3 Engineered to Endure Figure D 2 Fabrication Drawing FBD 21984 XXXX Rev B page 1 of 2 ...
Страница 181: ...Reference Drawings D 5 Engineered to Endure Figure D 4 Fabrication Drawing FBD 20606 XXXX Rev A ...
Страница 196: ...I n d e x 4 ...