6.3 INSTALLATION OF ACCESSORIES (OPTIONAL)
6.3.1 Installation of CXF-PC31
In case the CXF-PC31 device is purchased, it requires correct
fitting to the body of the machine.
NOTE
The operations indicated below are only carried out prior to the
connection of the cooler.
ATTENTION
Per l’installazione seguire le immagini mostrate sotto.
Open the the electrical panel and fasten it to the machine, as
shown in the picture, with 4 screws TSP 3.9 x22 (provided in the kit).
Connect the all the electrical components: the pump to the
terminals 24 and N1, and the motor to the terminals 2T, 4T and
6T of the switch, as shown in the wiring diagram from the panel
and at page 71.
F
inish the operation by closing the electrical panel with the pla
-
stic screws supplied.
6.3.2 Installation of the environment thermostat
ATTENTION
The electrical connection must be performed only by authorized
staff in accordance with the current national and local regulations.
ATTENTION
The environment thermostat which is used must be of second
class type or designed to be connected to earth.
The environment thermostat contacts must be united in the
special clamp terminal on the control panel inside the PERIcooler,
following the guidance on the wiring diagram and the sticker
applied to the clamps (see picture on page 11, terminals 3 and 4).
If the machine is provided with an external control panel, join
the environment thermostat by strictly following the wiring diagram
accompanying the accessory installed.
In the case of a fixed installation, it is advisable to install the
thermostat (or the probe) poiting away from the machine so that it
can function only when the desired temperature is reached.
6.3.3 Installation of the humidity indicator
ATTENTION
The electrical connection must be performed only by authorized
staff in accordance with the current national and local regulations.
The use of a humidity indicator allows the removal of voltage
from the pump when the humidity is considered inadequate
for proper and efficient use of the cooler, thereby improving the
environmental comfort condition.
The humidity indicator contacts must be connected to the clamp
terminal on the internal control panel of the PERIcooler following
the indications of the wiring diagram and the lablel attached to
the clamps.
If the machine is provided with an external control panel,
attach the humidity indicator strictly following the wiring diagram
accompanying the accessory installed.
6.3.4 Installation of the WSK
In case the WSK kit is purchased it requires correct fitting to the
body of the machine.
NOTE
The operations indicated below should occur only before
installing and connecting the cooler.
The WSK kit allows easy relocation of the machine (absolutely
important - with empty recipient) when not in use
.
ATTENTION
For installation, follow the pictures below.
Place the support
under the tank
(between the tank
and the side panel)