2-4 Platform Overload System
2-4
Platform Overload System
Proper calibration of the platform overload system
is essential to safe machine operation. Continued
use of an improperly calibrated platform overload
system could result in the system failing to sense
an overloaded platform.
How to C alibr ate the Pl atform Overl oad System
How to Calibrate the Platform
Overload System
Note: Perform this procedure with the machine on
a firm, level surface.
Note: The turntable level sensor must be calibrated
before performing this procedure.
1 Fully retract the boom. Level the platform.
2 Remove all material, tools and equipment
from the platform. Remove the welder (if
equipped).
Tip-over hazard. Failure to
remove all factory and
non-factory accessories could
result in the machine tipping
over, causing death or serious
injury.
3 Enter Service Mode. Refer to Repair
Procedure,
How to Enter the Service Mode
.
4 Press the settings button above the display
and select the Calibrations menu.
5 Navigate to the Sensor calibration screen.
6 Navigate to the Load Sense calibration
screen.
7 Select and start the calibration procedure.
8 Follow the on-screen instructions to set the
zero load.
9 Continue with the on screen prompts to set the
maximum load.
10 Place a 1,000 lb / 454 kg test weight on the
platform floor using a suitable lifting device.
Place the weight near the center entry point of
the platform, as far away from the operator
controls as possible.
11 Now continue to follow the prompts to accept
the weight.
12 The calibration is now complete.
13 Exit the Service Mode
Confirm the setting:
14 Lift the test weight off the platform floor using a
suitable lifting device.
15 Start the engine from the ground control.
16 Place a 1,000 lb / 454 kg test weight and an
additional 50 lbs / 23 kg on the platform floor.
Result: The alarm sounds. The platform
overload indicator light flashes at the platform
controls and
platform overload
is displayed on
the LCD screen at the ground controls. The
engine shuts down.
Note: There may be a 2 second delay before the
overload indicator lights flash and the alarm
sounds.
17 Test all machine functions from the ground
controls.
Result: Engine does not start or run. Limited
APU functionality. Primary boom up and
extend does not operate.
Remove the weight from the platform.
Содержание Genie S-80 HF Series
Страница 77: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 65 ...
Страница 87: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 75 ...
Страница 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Страница 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Страница 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Страница 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Страница 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Страница 192: ...Service and Repair Manual October 2019 180 Electrical Schematic 12 Kw Welder Generator and 3 kW Generator ...
Страница 193: ...October 2019 Service and Repair Manual 181 Hydraulic Schematics Hydraulic Schematic S 80 XC 4WD Models ...
Страница 197: ......