October 2019
Service and Repair Manual
Control System Fault Codes
Part No. 1280490GT
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
99
ID Component ID Name
Cause
Effect
Solution
41 Turntable
Rotate
Joystick
12 Joystick
voltage too
high.
Circuit C165TTR
is above 4.5 V.
Turntable
Rotate
functions will
not operate.
* Leave joystick in neutral position and
cycle power.
* If fault persists, with a voltmeter check
that C165TTR (WH/RD, PCON J18-2) is
at 2. 5V +/- 0.2 V at startup and does not
go above 4.5 V or below 0.5 V when fully
stroked in each direction.
* Replace joystick if voltage check fails.
15 Joystick
voltage too
low.
Circuit C165TTR
is below 0.5 V.
19 Joystick
held at
startup.
Circuit C165TTR
voltage was not
within the startup
voltage range of
2.5 V +/- 0.2 V.
42 Turntable
Rotate CW
Valve
12 Circuit
shorted to
V+
TCON detected
that C4TRL circuit
is shorted to 12 V.
Turntable
Rotate
functions will
not operate.
* With a voltmeter, measure Y24. Proper
resistance should be between 5 - 60
ohms. Replace Y24 if resistance is
outside of those values.
* Verify wiring for C4TRL (WH, TCON
J3-12) and check for open or short circuits.
15 Circuit
shorted to
GND
TCON detected
that C4TRL circuit
is shorted to
GND.
43 Turntable
Rotate CCW
Valve
12 Circuit
shorted to
V+
TCON detected
that C5TRR
circuit is shorted
to 12 V.
Turntable
Rotate
functions will
not operate.
* With a voltmeter, measure Y23. Proper
resistance should be between 5 - 60
ohms. Replace Y23 if resistance is
outside of those values.
* Verify wiring for C5TRR (WH/BK, TCON
J3-1) and check for open or short circuits.
15 Circuit
shorted to
GND
TCON detected
that C5TRR
circuit is shorted
to GND.
44 Drive Enable
Switch
19 Stuck ON at
power up.
Toggle switch
input was
detected as HIGH
at start-up.
Drive Enable
switch will
not operate,
possibly
preventing
drive while
the turntable
is rotated.
Verify with a voltmeter that the Drive
Enable Toggle Switch (TS15) is operating
properly.
* C143DEL (BL/RD, PCON J16-7) should
be 0 V with the switch OFF and 12 V with
the switch held in the ON position.
Cycle power to allow the machine to
re-test the fault.
45 Platform
Level
Up/Down
Switch
19 Stuck ON at
power up.
Toggle switch
input was
detected as HIGH
at start-up.
Platform
Level Up or
Down
functions
may not
operate,
depending
on which
direction the
switch fault
occurred.
Verify with a voltmeter that the Platform
Level Up/Down Toggle Switch (TS9) is
operating properly.
* C14PLU (OR, PCON J17-2) should be 0
V with the switch OFF and 12 V with the
switch held in the UP position.
* C15PLD (OR/BK, PCON J17-3) should
be 0 V with the switch OFF and 12 V with
the switch held in the DOWN position.
Cycle power to allow the machine to
re-test the fault.
Содержание Genie S-80 HF Series
Страница 77: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 65 ...
Страница 87: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 75 ...
Страница 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Страница 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Страница 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Страница 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Страница 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Страница 192: ...Service and Repair Manual October 2019 180 Electrical Schematic 12 Kw Welder Generator and 3 kW Generator ...
Страница 193: ...October 2019 Service and Repair Manual 181 Hydraulic Schematics Hydraulic Schematic S 80 XC 4WD Models ...
Страница 197: ......