Service and Repair Manual
October 2019
Control System Fault Codes
106
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
Part No. 1280490GT
ID Component ID Name
Cause
Effect
Solution
80 Turntable
Controller
(TCON)
13 Not
detected
The DISCON has
not detected the
TCON on the
CAN bus.
Machine will
not be
functional.
* Verify TCON is receiving power. Check for 12
V on J5-2 (+) and J5-1 (-).
* Verify TCON is receiving ESTOP signals. With
ground ESTOP pulled out and keyswitch set to
Ground, verify 12 V is reaching TCON J5-9 and
J5-12.
* Verify CAN bus is functional. Pull out
connector J5 from the TCON and with a
voltmeter set to resistance verify that pins 3 and
4 on the harness connector measure between
55 and 65 Ohms. Check wiring and boom cable
for open or short circuits if resistance check
fails.
* Replace TCON if necessary.
36 Incorrect
software
version
TCON's
secondary
processor
software revision
does not match
the system
revision level.
Reprogram the machine with latest software.
Check http://firmware.genielift.com/ for the
latest software version.
83 Telematics
21 Remote
disable
The telematics
module has
locked out
machine
operation.
Machine will
not be
functional, or
have limited
functionality,
depending
on the
telematics
option.
Call machine owner to re-enable machine
functions.
84 Turntable Tilt
Sensor
13 Not
detected
The tilt sensors
(S8O and/or S8S)
have not been
detected on the
CAN bus.
Boom Up,
Extend and
Drive
functions will
not operate.
* Verify S8O is receiving power. Disconnect
sensor connector and verify harness connector
pins 1 and 2 measure 12 V.
* Verify S8S is receiving power. Disconnect
sensor connector and verify harness connector
pins 1 and 2 measure 12 V.
* Verify CAN bus wiring. With a voltmeter set to
resistance, check the resistance between pins 3
and 4 on the harness connector (not the
sensor's integrated connector). Resistance
should be between 55 and 65 ohms. Check
CAN wiring if resistance check fails.
* Replace sensor if required.
17 Invalid
calibration
The tilt sensors
have no valid
calibration data,
either because
the sensor(s)
were replaced or
the prior
calibration was
cleared from
memory or was
unsuccessful.
Boom Up
and Extend
functions will
not operate.
Perform the tilt sensor calibration process.
Содержание Genie S-80 HF Series
Страница 77: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 65 ...
Страница 87: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 75 ...
Страница 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Страница 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Страница 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Страница 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Страница 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Страница 192: ...Service and Repair Manual October 2019 180 Electrical Schematic 12 Kw Welder Generator and 3 kW Generator ...
Страница 193: ...October 2019 Service and Repair Manual 181 Hydraulic Schematics Hydraulic Schematic S 80 XC 4WD Models ...
Страница 197: ......