October 2019
Service and Repair Manual
Deutz D 2.9 L4 Engine Fault Codes
Part No. 1280490GT
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
133
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN FMI KWP
Description
1188 7
1415
Wastegate actuator; blocked
1188 11
1411
Wastegate actuator; internal
error
1188 11
1412
Wastegate actuator; EOL
calibration not performed
correctly
1188 11
1416
Wastegate actuator; over
temperature (> 145øC)
1188 11
1417
Wastegate actuator; over
temperature (> 135øC)
1188 11
1418
Wastegate actuator; operating
voltage error
1188 13
1413
Wastegate actuator calibration
deviation too large, recalibration
required
1231 14
85
CAN-Bus 1 "BusOff-Status"
1235 14
86
CAN-Bus 2 "BusOff-Status"
1237 2
747
Override switch; plausibility error
1322 12
610
Too many recognized misfires in
more than one cylinder
1323 12
604
Too many recognized misfires in
cylinder 1 (in firing order)
1324 12
605
Too many recognized misfires in
cylinder 2 (in firing order)
1325 12
606
Too many recognized misfires in
cylinder 3 (in firing order)
1326 12
607
Too many recognized misfires in
cylinder 4 (in firing order)
2659 0
1524
Physical range check high for
EGR exhaust gas mass flow
2659 1
1525
Physical range check low for
EGR exhaust gas mass flow
2659 2
1523
Exhaust gas recirculation AGS
sensor; plausibility error
SPN FMI KWP
Description
2659 2
1527
AGS sensor temperature
exhaust gas mass flow;
plausibility error
2659 12
1526
Exhaust gas recirculation; AGS
sensor has "burn off" not
performed
2797 4
1337
Injector diagnostics; timeout error
of short circuit to ground
measurement cyl. Bank 0
2798 4
1338
Injector diagnostics; timeout error
of short circuit to ground
measurement cyl. Bank 1
2798 4
1339
Injector diagnostics; short circuit
to ground monitoring Test in Cyl.
Bank 0
2798 4
1340
Injector diagnostics; short circuit
to ground monitoring Test in Cyl.
Bank 1
3224 2
127
DLC Error of
CAN-Receive-Frame AT1IG1
NOX Sensor (SCR-system
upstream cat; DPF-system
downstream cat); length of frame
incorrect
3224 9
128
Timeout Error of
CAN-Receive-Frame AT1IG1;
NOX sensor upstream
3248 4
1047
Sensor error particle filter
downstream temperature; signal
range check low
3699 2
1616
DPF differential pressure sensor
and a further sensor or actuator
CRT system defective
3699 2
1617
Temperature sensor us. and ds.
DOC simultaneously defect
3699 14
1615
Maximum stand-still-duration
reached; oil exchange required
4765 0
1039
Physical range check high for
exhaust gas temperature
upstream (DOC)
4765 1
1042
Physical range check low for
exhaust gas temperature
upstream (DOC)
Содержание Genie S-80 HF Series
Страница 77: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 65 ...
Страница 87: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 75 ...
Страница 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Страница 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Страница 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Страница 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Страница 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Страница 192: ...Service and Repair Manual October 2019 180 Electrical Schematic 12 Kw Welder Generator and 3 kW Generator ...
Страница 193: ...October 2019 Service and Repair Manual 181 Hydraulic Schematics Hydraulic Schematic S 80 XC 4WD Models ...
Страница 197: ......