October 2019
Service and Repair Manual
Control System Fault Codes
Part No. 1280490GT
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
119
ID Component ID Name Cause
Effect
Solution
61 Steer
Joystick
11 Shorted
to
supply
voltage
Circuit C159STD or
C159STA is above
4.5 V.
Drive and steer
functions will not
operate.
* Leave joystick in neutral position and
cycle power.
* If fault persists, identify which circuit
is the steer circuit. Check C159STA
(BL/WH, PCON J18-11) for a joystick
steer option. Check C159STD (BL/RD,
PCON J18-9) for the rocker joystick
steer option. With a voltmeter check
that the circuit is at 2. 5V +/- 0.2 V at
startup and does not go above 4.5 V or
below 0.5 V when fully stroked in each
direction.
* Replace joystick if voltage check
fails.
27 Active
at
startup
Circuit C159STD or
C159STA voltage
was not within the
startup voltage
range of 2.5 V +/-
0.2 V.
62 Prox
Override
Togggle
Switch
27 Active
at
startup
Toggle switch input
was detected as
HIGH at start-up.
The Jib Up or Down
functions will not
operate.
*Verify with a voltmeter that the Jib
Up/Down Toggle Switch (TS8) is
operating properly.
* C43JU (BL, PCON J17-6) should be
0 V with the switch OFF and 12 V with
the switch held in the UP position.
* C44JD (BL/BK, PCON J17-8) should
be 0 V with the switch OFF and 12 V
with the switch held in the DOWN
position.
Cycle power to allow the machine to
re-test the fault.
68 Ground
Function
Enable
Button
27 Active
at
startup
Button was held at
system start, or is
shorted on the
ground control
panel.
The function
associated with the
stuck button will not
operate.
* Release the ground control buttons
and cycle power. * If problem persists,
open ground control box and open the
Display Controller access door, being
careful to keep water out. Verify the
ribbon cables are properly seated and
dry.
* Re-seat and/or replace ribbon cables
if necessary.
* Replace ground control overlay.
Содержание Genie S-80 HF Series
Страница 77: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 65 ...
Страница 87: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 75 ...
Страница 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Страница 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Страница 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Страница 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Страница 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Страница 192: ...Service and Repair Manual October 2019 180 Electrical Schematic 12 Kw Welder Generator and 3 kW Generator ...
Страница 193: ...October 2019 Service and Repair Manual 181 Hydraulic Schematics Hydraulic Schematic S 80 XC 4WD Models ...
Страница 197: ......