Service and Repair Manual
October 2019
Deutz D 2.9 L4 Engine Fault Codes
136
S
®
-80 XC
™
• S
®
-85 XC
™
•
S
®
-
80 HF • S
®
-85 HF
Part No. 1280490GT
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP Description
523717 12 125 Timeout Error of
CAN-Transmit-Frame AmbCon;
Weather environments
523718 3
1488 SCR mainrelay; short circuit to
battery (only CV56B)
523718 4
1489 SCR mainrelay; short circuit to
ground (only CV56B)
523718 5
1486 SCR mainrelay; open load (only
CV56B)
523718 12 1487 SCR mainrelay; powerstage over
temperature (only CV56B)
523766 9
281 Timeout Error of
CAN-Receive-Frame Active
TSC1AE
523767 9
282 Timeout Error of
CAN-Receive-Frame Passive
TSC1AE
523768 9
283 Timeout Error of
CAN-Receive-Frame Active
TSC1AR
523769 9
284 Timeout Error of
CAN-Receive-Frame Passive
TSC1AR
523770 9
285 Timeout Error of
CAN-Receive-Frame Passive
TSC1DE
523776 9
291 Timeout Error of
CAN-Receive-Frame TSC1TE -
active
523777 9
292 Passive Timeout Error of
CAN-Receive-Frame TSC1TE;
Setpoint
523778 9
293 Active Timeout Errorof
CAN-Receive-Frame TSC1TR
523779 9
294 Passive Timeout Error of
CAN-Receive-Frame TSC1TR
SPN
FMI KWP Description
523788 12 299 Timeout Error of
CAN-Transmit-Frame TrbCH;
Status Wastegate
523793 9
202 Timeout Error of
CAN-Receive-Frame UAA10;
AGS sensor service message
523794 9
203 Timeout Error of
CAN-Receive-Frame UAA11;
AGS sensor data
523895 13 559 Check of missing injector
adjustment value programming
(IMA) injector 1 (in firing order)
523896 13 560 check of missing injector
adjustment value programming
(IMA) injector 2 (in firing order)
523897 13 561 check of missing injector
adjustment value programming
(IMA) injector 3 (in firing order)
523898 13 562 check of missing injector
adjustment value programming
(IMA) injector 4 (in firing order)
523910 6
1261 Air Pump; over current
523913 3
74
Sensor error glow plug control
diagnostic line voltage; signal
range check high
523913 4
75
Sensor error glow plug control
diagnostic line voltage; signal
range check low
523914 3
78
Glow plug control; short circuit to
battery
523914 4
79
Glow plug control; short circuit to
ground
523914 5
76
Glow plug control; open load
523914 5
1216 Glow plug control release line;
short circuit error
523914 11 1217 Glow plug control; internal error
523914 12 77
Glow plug control; powerstage
over temperature
523919 2
1378 Sensor air pump airpressure;
plausibility error
523920 2
1379 Sensor exhaust gas back
pressure burner; plausibility error
Содержание Genie S-80 HF Series
Страница 77: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 65 ...
Страница 87: ...October 2019 Service and Repair Manual Manifolds Part No 1280490GT S 80 XC S 85 XC S 80 HF S 85 HF 75 ...
Страница 181: ...October 2019 Service and Repair Manual 169 Electrical Schematic Deutz TD2 9 L4 Engine ...
Страница 184: ...Service and Repair Manual October 2019 172 Electrical Schematic Deutz TD2011 Engine ...
Страница 185: ...October 2019 Service and Repair Manual 173 Electrical Schematic Perkins 404D 22T Engine ...
Страница 188: ...Service and Repair Manual October 2019 176 Electrical Schematic Perkins 404F E22TA Engine ...
Страница 189: ...October 2019 Service and Repair Manual 177 Electrical Schematic GM 3 0L Engine ...
Страница 192: ...Service and Repair Manual October 2019 180 Electrical Schematic 12 Kw Welder Generator and 3 kW Generator ...
Страница 193: ...October 2019 Service and Repair Manual 181 Hydraulic Schematics Hydraulic Schematic S 80 XC 4WD Models ...
Страница 197: ......