![Terex Genie GS-2669DC Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/terex/genie-gs-2669dc/genie-gs-2669dc_operators-manual_1088654047.webp)
Second Edition • Second Printing
Operator's Manual
Operating Instructions
Part No. 1305659GT
GS
™
-2669DC • GS
™
-3369DC • GS
™
-4069DC
45
Platform Overload
If the platform controls LED diagnostic readout
displays a flashing OL and the ground controls
LCD diagnostic readout displays OL: Platform
Overloaded, the platform is overloaded and no
functions will operate. An alarm will sound.
1 Push in the Red Emergency stop button to the
off position.
2 Remove weight from the platform.
3 Pull out the Red Emergency Stop button to the
on position.
LED Readout
LCD Readout
Operational indicator codes
If the platform controls LED or ground controls
LCD diagnostic readout displays an operational
indicator code such as LL, the fault condition must
be repaired or removed before resuming machine
operation. Push in and pull out the red Emergency
Stop button to reset the system.
LED Readout
LCD Readout
Operational Indicator Codes
Code
Condition
LL
Off-Level
OL
Platform Overloaded
CH
Chassis Mode Operation
Nd
No Drive (option)
Ld
Lifiting Disabled
F053
DCON RR Thermal Protection
F054
DCON LR Thermal Protection
F055
Traction Motor RR Fault: Motor Temp
F056
Traction Motor LR Fault: Motor Temp
For further information, please consult the
appropriate Genie Service Manual. A code and a
description of a code can also be viewed at the
ground controls LCD display.
Содержание Genie GS-2669DC
Страница 60: ......