Possible Cause
Solution
Problem
Generator will not hold voltage
(loss of residual magnetism)
Machine has been unused for
signifi cant length of time
Flash the rotor
Rotor shorting out when unit gets
hot
Inspect rotor windings for broken
and/or burned wires
Pinched leads
Inspect and repair as needed
Faulty capacitor
Replace
Faulty diode
Replace
Faulty surge suppressor
Replace
Generator voltage low
Loss of residual magnetism
Flash the rotor
Low engine speed
Adjust idle. See Repair Section.
Faulty diode
Replace
Generator voltage spikes
Incorrect engine adjustment, fuel
line or faulty fuel
Change fuel fi lter and check
engine speed
Loose connection
Inspect all connections and repair
as needed
Faulty ground connection
Inspect all ground connections
and repair as needed
Load induced
Filter load
TROUBLESHOOTING
Faulty capacitor
Replace