August 2016
3 - 32
AL4 • AL4000
Part No. 218567
Section 3 • Scheduled Maintenance Procedures
E-1
Replace the Mast Lift Cable
Terex specifi cations require that this procedure be
performed every two years.
The mast cable is responsible for the raising
and lowering of the mast and lights. Regular
replacement of the mast cables is essential to
good machine performance and safe machine
operation.
1 Replace the mast lift cable. Refer to Repair
Procedure 1-1,
How to Replace the Mast Lift
Cable
.
E-2
Perform Engine Maintenance
Engine specifi cations require that this procedure
be performed every 2000 hours or bi-annually,
whichever comes fi rst.
Kubota D1105:
• Replace coolant
• Replace radiator hoses and clamps
• Replace fuel hoses and clamps
• Replace air intake hose and clamps
Perkins 403D-11:
• Inspect alternator
• Replace crankcase breather
• Inspect engine mounts
• Inspect starter
Required maintenance procedures and additional
engine information is available in the
Kubota D1105 Operators Manual
(Kubota part number 16622-89166) OR the
Perkins 403D-11 User's Handbook
(Perkins part number SEBU8311-01).
Kubota D1105 Operators Manual
Genie part number
131379
Perkins 403D-11 User's Handbook
Genie part number
131661
Checklist E Procedures
Discount-Equipment.com