Section 3 • Scheduled Maintenance Procedures
August 2016
Part No. 218567
AL4 • AL4000
3 - 29
C-6
Perform Generator Maintenance
Leroy Somer Models
Generator specifi cations require that this
procedure be performed every 2000 hours or
semi-annually, whichever comes fi rst.
Maintaining the generator in good condition is
essential to safe machine operation and long
service life. Storing the generator in a harsh
environment may require this procedure be
performed more frequently. Loose or damaged
connections or components may result in a
generator to lose effi ciency, and reduce the life of
the generator.
• Inspect stator output leads and insulation for
cracking and damage
• Inspect exposed electrical for loose or damaged
connections
• Inspect transformers, fuses, capacitors and
lighting arrestors for loose or damaged
component connections
• Inspect all wire and electrical connections for
proper clearance
• Inspect and clean inside of outlet box, air
screens and air baffl es with compressed air
• Inspect for machine vibration and bearing wear
Leroy Somer Manual
Genie part number
116118
CHECKLIST C PROCEDURES
Discount-Equipment.com