Section 3 • Scheduled Maintenance Procedures
August 2016
Part No. 218567
AL4 • AL4000
3 - 13
A-16
Perform Generator Maintenance
Marathon Models
Generator specifi cations require that this
procedure be performed every 200 hours or
quarterly, whichever comes fi rst.
Maintaining the generator in good condition is
essential to safe machine operation and long
service life. Storing the generator in a harsh
environment may require this procedure be
performed more frequently. Allowing dirt and
grease to build up on the generator may result in a
generator which will run hotter, lose effi ciency, and
reduce the life of the generator.
• Clean and inspect the generator exterior
• Clean and inspect the inside of the capacitor
box. Check for loose or damaged wires and
components.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Marathon Manual
Genie part number
116188
a capacitor
box
b generator
A-15
Perform Engine Maintenance -
Kubota Models
Engine specifi cations require that this procedure
be performed every 200 hours.
• Change engine oil
• Replace oil fi lter
• Inspect radiator hoses and clamps
• Inspect air intake hose
Required maintenance procedures and additional
engine information is available in the
Kubota D1105 Operator's Manual
(Kubota part number 16622-89166) OR the
Kubota D1105 Operator's Manual
Genie part number
131379
CHECKLIST A PROCEDURES
Discount-Equipment.com