background image

12 

 

CONTRAINDICATIONS:  

 

Do  NOT  use 

if  you  are  or  may  be 

pregnant.

  It  is  not  known  whether 

TENS 

may 

affect 

foetal 

development. 

 

Do NOT use

 with optional electrode 

pads if you have a pacemaker (or  if 
you have a heart rhythm problem) or 
with any electronic medical devices. 

Using  this  unit  with  electronic 
medical 

devices 

may 

cause 

erroneous  operation  of  the  device. 
Stimulation in the direct vicinity of an 
implanted  device  may  affect  some 
models.  Stimulation  on  the  front  of 
the  neck  can  affect  your  heart  rate. 
Very  strong  stimulation  across  the 
chest may cause an extra heartbeat.

 

 

Do  NOT  use

  in  the  first

 

6  weeks 

following a pelvic surgery or vaginal 
childbirth. 

Stimulation  may  disrupt 

the healing process.

 

 

Do NOT use

 if you have symptoms 

of  active  urinary  tract  infection, 
vaginal 

infections, 

or 

localized 

lesions. 

Introducing  the  probe  may 

irritate sensitive tissue. 

 

 

Do  NOT  use

  if  you  have  poor 

sensation  in  the  pelvic  region. 

You 

may  not  be  able  to  control  the 
intensity of stimulation safely.

 

 

WARNINGS:  

Do NOT use

 if you are unable 

to properly insert the vaginal or 

anal  probe.  If  you  have  a  severe 
prolapse,  or  if  any  discomfort  occurs 
when inserting the probe, consult your 
healthcare professional before use. 

Do  NOT  use 

when  driving, 

operating machinery, or similar 

actions 

needing 

muscular 

control.  

Loose 

electrode 

pads, 

damaged leads, or sudden changes in 
contact  may  cause  brief  involuntary 
muscle movements. 

Do NOT use 

to mask or relieve 

undiagnosed  pain. 

This  may 

delay  diagnosis  of  a  progressive 
condition. 

Do NOT use

 if you have, in the 

area  being  treated:  active  or 

suspected cancer or undiagnosed pain 
with  a  history  of  cancer. 

Stimulation 

directly 

through 

confirmed 

or 

suspected 

malignancy 

should 

be 

avoided as it may stimulate growth and 
promote spread of cancer cells. 

 

CAUTIONS: 

Caution

 should be used if you 

have  suspected  or  diagnosed 

epilepsy  as  electrical  stimulation  may 
affect seizure threshold. 

Caution

  should  be  observed 

when  using  the  device  at the 

same  time  as  being  connected  to 
monitoring 

equipment 

with 

body 

worn electrode  pads. 

It  may  interfere 

with the signals being monitored.

 

Caution:

 

Simultaneous 

connection  to  high  frequency 

surgical equipment may result in burns 
and damage to the stimulator.  

Caution:

 

Strong 

electromagnetic fields (electro-

surgery/  microwave  cookers/  mobile 
phones) 

may 

affect 

the 

correct 

operation  of  this  unit.  If  it  appears  to 
behave  unusually,  move  it  away  from 
these devices.  

Caution

 Do  not  permit  use  by 

persons  unable  to  understand 

the  instructions  or  persons  with 
cognitive  disabilities,  i.e.;  Alzheimer’s 
disease or dementia. 

Содержание Perfect PFE

Страница 1: ...0 INSTRUCTIONS FOR USE READ CAREFULLY BEFORE USE...

Страница 2: ...ert the vaginal probe Press and hold the ON button to switch the device on Regulate the output intensity with the buttons and Press and hold the OFF button to switch the device off ON Button P UP DOWN...

Страница 3: ...y tested products for the applications in the areas of gentle electrotherapy muscle toning continence management and pain relief during labour Please read these instructions for use carefully and keep...

Страница 4: ...GRAMMES 15 11 CONTENT 16 12 UNIT INFORMATION 17 12 1 CONTROLS DISPLAY 17 12 2 OPERATING INSTRUCTIONS 18 13 SETTING UP AND USING THE PERFECT PFE 20 13 1 INSTALLATION OF BATTERIES 20 13 2 CONNECTING LEA...

Страница 5: ...ue number so that the device can be identified This medical device is not water resistant and should be protected from liquids Atmospheric Pressure indicates the atmospheric limits to which the medica...

Страница 6: ...ectly complements pelvic floor exercises The perfect PFE is very easy to use with four clearly labelled preset training programmes a fifth programme for chronic pelvic pain and a simple push button co...

Страница 7: ...h to zero and flashes LEADS if the connection comes loose Automatic Keypad Lock Automatic keypad lock prevents any accidental changes in settings Large LCD Screen Clearly shows the operation of the un...

Страница 8: ...as a bulge in the vagina or a feeling of heaviness discomfort pulling dragging or dropping This occurs when one or more of the pelvic organs bladder bowel or uterus become displaced and sag down into...

Страница 9: ...g the muscles you identified earlier don t tense the muscles in your legs stomach or buttocks and remember to breathe normally 4 Aim to hold each squeeze or contraction for three to five seconds then...

Страница 10: ...in medical rehabilitation and training in competitive sports EMS produces intensive and effective muscular contraction In rehabilitation EMS is a well established method for treatment of a broad field...

Страница 11: ...ion medium frequencies 20 50 Hz can put a high level of strain on the muscle thus promoting the muscular structure Each preset programme has a specific frequency and pulse width that will offer the be...

Страница 12: ...sis see Ova cystitis sports injuries Raynaud disease fibromyalgia and neuralgia plantar fasciitis post operative pain and sometimes non painful conditions such as tiredness insomnia travel sickness ti...

Страница 13: ...ofessional before use Do NOT use when driving operating machinery or similar actions needing muscular control Loose electrode pads damaged leads or sudden changes in contact may cause brief involuntar...

Страница 14: ...unless the control unit is powered OFF as insertion or removal when stimulation is active may cause discomfort or tissue irritation Caution If tissue irritation occurs discontinue treatment immediate...

Страница 15: ...ay affect the sockets or cause the battery connector to develop a bad contact Caution Temperature Relative Humidity of storage 20 C 40 C 8 70 R H Temperature Relative Humidity of transportation 20 C 4...

Страница 16: ...t starts becoming apparent after about four weeks The sensation is like a strong drawing in of the muscles of the vagina pulling up the pelvic floor Your natural reaction will be to pull your muscles...

Страница 17: ...ng the TONE programme is a mixture of a strong drawing in of the muscles and then releasing A strong and fit pelvic floor may increase sexual health and enjoyment PAIN Shown on the screen as PAIN The...

Страница 18: ...TION 12 1 CONTROLS DISPLAY Programme selected Programme selector Time selector OFF button ON button Keypad Lock Programme duration min Strength selected mA Strength up Strength down Low Battery Output...

Страница 19: ...unit will remain in the WORK part of the cycle for 5 seconds while intensity is being adjusted The strength levels are shown on the LCD The strength control buttons will not operate until the unit is...

Страница 20: ...unlock press and hold the strength down control button LEADS ALARM The perfect PFE monitors the connection and the contact between you and the probe or the pads This is to prevent sudden changes if a...

Страница 21: ...nit is unlikely to be used for a long period Some types of batteries may leak corrosive fluid Battery Life Batteries should last about 18 hours at full power Unused batteries have a nominal shelf life...

Страница 22: ...rientation makes no difference and you can ignore this colour coding 13 3 PREPARING FOR SESSION 1 Before using perfect PFE you will need to visit the toilet 2 Lubricate the metal electrode surfaces an...

Страница 23: ...ed P in the centre of the control unit keypad 3 With the required programme selected you can adjust the intensity of the muscle stimulation until you reach a comfortable level Once you have reached a...

Страница 24: ...strength display on the control unit will reduce to 0 and flash during the rest period The URGE and PAIN programmes work differently There is no need to have a contraction The strength should be comfo...

Страница 25: ...be restricted to one muscle group and the mucosal tissue has different electrical characteristics anal stimulation is less comfortable than vaginal You should consult your healthcare professional bef...

Страница 26: ...d otherwise by a healthcare professional 5 Anal probes with long electrodes the metal part that run up and down the length of the attachment should always be inserted with the metal parts facing hip t...

Страница 27: ...label from our website www tenscare co uk attach this to an envelope or padded bag with the unit enclosed and post it back to us Upon receipt we will process your old device for components recovery a...

Страница 28: ...e from manufacturing defects for 2 years from date of purchase This warranty is void if the product is modified or altered is subject to misuse or abuse damaged in transit lack of responsible care is...

Страница 29: ...chase receipt Please ensure all relevant details are completed before sending your unit in for service Please ensure your contact details are still current and include a brief description of the probl...

Страница 30: ...ill also prevent anyone from increasing the intensity to a high level without firm contact between the machine and the skin A connection error can occur if 1 A break has developed within one of the tw...

Страница 31: ...appen in childbirth or some surgical procedures Please consult your healthcare professional No sensation on one side of the probe or electrode Position is not optimal needs adjusting The current flows...

Страница 32: ...g Atmospheric pressure 700hPa to 1060hPa Temperature range 25 70 C Humidity Up to 93 RH non condensing Atmospheric pressure 700hPa to 1060hPa TYPE BF EQUIPMENT Equipment providing a degree of protecti...

Страница 33: ...ANTY NAME ADDRESS POSTCODE DAYTIME TELEPHONE E MAIL MODEL DATE OF PURCHASE ATTACH PROOF OF PURCHASE DO NOT SEND IN PROBE OR ELECTRODE PADS RETAILERS NAME RETAILERS ADDRESS RETAILERS POSTCODE BRIEF DES...

Страница 34: ...33 NOTES...

Страница 35: ...e limited https plus google com TenscareLtdEpsom https uk pinterest com TensCareLtd https tenscareltd wordpress com https www youtube com channel UCzpik9dmLlJ3j0aHOpQ 0sg EC Declaration of Conformity...

Страница 36: ...35 Distributed by Manufactured by TensCare Ltd 9 Blenheim Road Epsom Surrey KT19 9BE UK Tel 44 0 1372 723434 www tenscare co uk Pub No I PPFE UK Version 2 2 05 17...