background image

18 

 

12.2. OPERATING 

INSTRUCTIONS 

ON/OFF  

To turn the unit on, press the 

ON

 button and hold for 3 to 5 

seconds  until  the  display 
shows. 

To  turn  the 

unit off,  press  ▼ 

button to remove keypad lock and press 
the 

OFF

  button  and  hold  for  3  to  5 

seconds until the display stops. 

At first use, or after changing batteries, 
the  display  shows  that  the  unit  is 
automatically set in programme 

STRES

 

at zero strength.  

When  switched  on  the  unit  will 
automatically  start  in  the  programme 
which was being used when it was last 
switched off.  

The unit will turn off automatically: 

  When the Timer reaches zero, 

  If  it  is  left  at  zero  strength  for  more 

than 5 minutes. 

Note:

  Always  check  unit  is 

OFF 

before 

applying 

or 

removing probe or pads. 

 

The  backlight  will  turn  off  10  seconds 
after the last button press. 

 

STRENGTH CONTROLS 

The buttons marked 

▲ and ▼ 

are the strength controls.  

To  increase  strength,  press 
and  hold  down  the  button 

▲ 

until  required  strength  is 

achieved.  

To  decrease  the  strength,  press  and 
release the button 

▼.  

To increase strength in steps of 1 mA, 
press and release the button 

▲. 

The unit will remain  in the WORK part 
of  the  cycle  for  5  seconds  while 
intensity is being adjusted. 

The  strength  levels  are  shown  on  the 
LCD. 

The strength control buttons will not 
operate  until  the  unit  is  properly 
connected  to  you  (probe  inserted 
correctly).  Perfect  PFE  detects  a 
disconnection  and  automatically 
returns the strength to zero. 

 

The unit has 99 levels of strength. If you 
hold  down  the  button 

▲  for  3  to  5 

seconds, the strength will start scrolling. 

You may feel nothing over the first few 
presses.  Continue  pressing  until  the 
sensation  is  strong  but  comfortable. 
Further  increases  during  use  may  be 
necessary  if  your  body  becomes  used 
to the sensation.  

The  yellow  LED  on  the  output  socket 
indicates that there is an active output. 
The display will remain on for 5 seconds 
after the plug is removed. 

 

PROGRAMME CONTROL 

The  button  marked 

P

  is  the 

programme 

control. 

The 

perfect 

PFE

 

has 

five 

preset 

programmes.  At  first  use,  the  unit 
automatically  goes  to  programme 

STRES

.  Next  time  it  is  switched  on,  it 

will default to the programme used last. 

Each time you press and release the 

P

 

button, the programme changes and is 
shown on the LCD. 

Each time you change the programme, 
the strength level reverts back to zero. 
This is a safety feature to alleviate any 

ON 

 

OFF 

▲ 

▼ 

Содержание Perfect PFE

Страница 1: ...0 INSTRUCTIONS FOR USE READ CAREFULLY BEFORE USE...

Страница 2: ...ert the vaginal probe Press and hold the ON button to switch the device on Regulate the output intensity with the buttons and Press and hold the OFF button to switch the device off ON Button P UP DOWN...

Страница 3: ...y tested products for the applications in the areas of gentle electrotherapy muscle toning continence management and pain relief during labour Please read these instructions for use carefully and keep...

Страница 4: ...GRAMMES 15 11 CONTENT 16 12 UNIT INFORMATION 17 12 1 CONTROLS DISPLAY 17 12 2 OPERATING INSTRUCTIONS 18 13 SETTING UP AND USING THE PERFECT PFE 20 13 1 INSTALLATION OF BATTERIES 20 13 2 CONNECTING LEA...

Страница 5: ...ue number so that the device can be identified This medical device is not water resistant and should be protected from liquids Atmospheric Pressure indicates the atmospheric limits to which the medica...

Страница 6: ...ectly complements pelvic floor exercises The perfect PFE is very easy to use with four clearly labelled preset training programmes a fifth programme for chronic pelvic pain and a simple push button co...

Страница 7: ...h to zero and flashes LEADS if the connection comes loose Automatic Keypad Lock Automatic keypad lock prevents any accidental changes in settings Large LCD Screen Clearly shows the operation of the un...

Страница 8: ...as a bulge in the vagina or a feeling of heaviness discomfort pulling dragging or dropping This occurs when one or more of the pelvic organs bladder bowel or uterus become displaced and sag down into...

Страница 9: ...g the muscles you identified earlier don t tense the muscles in your legs stomach or buttocks and remember to breathe normally 4 Aim to hold each squeeze or contraction for three to five seconds then...

Страница 10: ...in medical rehabilitation and training in competitive sports EMS produces intensive and effective muscular contraction In rehabilitation EMS is a well established method for treatment of a broad field...

Страница 11: ...ion medium frequencies 20 50 Hz can put a high level of strain on the muscle thus promoting the muscular structure Each preset programme has a specific frequency and pulse width that will offer the be...

Страница 12: ...sis see Ova cystitis sports injuries Raynaud disease fibromyalgia and neuralgia plantar fasciitis post operative pain and sometimes non painful conditions such as tiredness insomnia travel sickness ti...

Страница 13: ...ofessional before use Do NOT use when driving operating machinery or similar actions needing muscular control Loose electrode pads damaged leads or sudden changes in contact may cause brief involuntar...

Страница 14: ...unless the control unit is powered OFF as insertion or removal when stimulation is active may cause discomfort or tissue irritation Caution If tissue irritation occurs discontinue treatment immediate...

Страница 15: ...ay affect the sockets or cause the battery connector to develop a bad contact Caution Temperature Relative Humidity of storage 20 C 40 C 8 70 R H Temperature Relative Humidity of transportation 20 C 4...

Страница 16: ...t starts becoming apparent after about four weeks The sensation is like a strong drawing in of the muscles of the vagina pulling up the pelvic floor Your natural reaction will be to pull your muscles...

Страница 17: ...ng the TONE programme is a mixture of a strong drawing in of the muscles and then releasing A strong and fit pelvic floor may increase sexual health and enjoyment PAIN Shown on the screen as PAIN The...

Страница 18: ...TION 12 1 CONTROLS DISPLAY Programme selected Programme selector Time selector OFF button ON button Keypad Lock Programme duration min Strength selected mA Strength up Strength down Low Battery Output...

Страница 19: ...unit will remain in the WORK part of the cycle for 5 seconds while intensity is being adjusted The strength levels are shown on the LCD The strength control buttons will not operate until the unit is...

Страница 20: ...unlock press and hold the strength down control button LEADS ALARM The perfect PFE monitors the connection and the contact between you and the probe or the pads This is to prevent sudden changes if a...

Страница 21: ...nit is unlikely to be used for a long period Some types of batteries may leak corrosive fluid Battery Life Batteries should last about 18 hours at full power Unused batteries have a nominal shelf life...

Страница 22: ...rientation makes no difference and you can ignore this colour coding 13 3 PREPARING FOR SESSION 1 Before using perfect PFE you will need to visit the toilet 2 Lubricate the metal electrode surfaces an...

Страница 23: ...ed P in the centre of the control unit keypad 3 With the required programme selected you can adjust the intensity of the muscle stimulation until you reach a comfortable level Once you have reached a...

Страница 24: ...strength display on the control unit will reduce to 0 and flash during the rest period The URGE and PAIN programmes work differently There is no need to have a contraction The strength should be comfo...

Страница 25: ...be restricted to one muscle group and the mucosal tissue has different electrical characteristics anal stimulation is less comfortable than vaginal You should consult your healthcare professional bef...

Страница 26: ...d otherwise by a healthcare professional 5 Anal probes with long electrodes the metal part that run up and down the length of the attachment should always be inserted with the metal parts facing hip t...

Страница 27: ...label from our website www tenscare co uk attach this to an envelope or padded bag with the unit enclosed and post it back to us Upon receipt we will process your old device for components recovery a...

Страница 28: ...e from manufacturing defects for 2 years from date of purchase This warranty is void if the product is modified or altered is subject to misuse or abuse damaged in transit lack of responsible care is...

Страница 29: ...chase receipt Please ensure all relevant details are completed before sending your unit in for service Please ensure your contact details are still current and include a brief description of the probl...

Страница 30: ...ill also prevent anyone from increasing the intensity to a high level without firm contact between the machine and the skin A connection error can occur if 1 A break has developed within one of the tw...

Страница 31: ...appen in childbirth or some surgical procedures Please consult your healthcare professional No sensation on one side of the probe or electrode Position is not optimal needs adjusting The current flows...

Страница 32: ...g Atmospheric pressure 700hPa to 1060hPa Temperature range 25 70 C Humidity Up to 93 RH non condensing Atmospheric pressure 700hPa to 1060hPa TYPE BF EQUIPMENT Equipment providing a degree of protecti...

Страница 33: ...ANTY NAME ADDRESS POSTCODE DAYTIME TELEPHONE E MAIL MODEL DATE OF PURCHASE ATTACH PROOF OF PURCHASE DO NOT SEND IN PROBE OR ELECTRODE PADS RETAILERS NAME RETAILERS ADDRESS RETAILERS POSTCODE BRIEF DES...

Страница 34: ...33 NOTES...

Страница 35: ...e limited https plus google com TenscareLtdEpsom https uk pinterest com TensCareLtd https tenscareltd wordpress com https www youtube com channel UCzpik9dmLlJ3j0aHOpQ 0sg EC Declaration of Conformity...

Страница 36: ...35 Distributed by Manufactured by TensCare Ltd 9 Blenheim Road Epsom Surrey KT19 9BE UK Tel 44 0 1372 723434 www tenscare co uk Pub No I PPFE UK Version 2 2 05 17...

Отзывы: