background image

 

5.  TYPES 

OF 

INCONTINENCE  

There are  three  types of  incontinence: 
Stress, Urge, and Mixed. 

 

Stress Incontinence

 

If  you  leak  urine  when  you  cough, 
sneeze,  laugh,  strain  or  make  sudden 
movements,  this  is  called  Stress 
Incontinence.  

It is particularly common in women who 
have had a natural childbirth and occurs 
when  the  bladder  neck  and  the  other 
mechanisms that act to hold urine in the 
bladder  are  not  working  properly.  The 
most  common  cause  is  a  weak  pelvic 
floor. 

Urge Incontinence

  

Describes  an  overactive  bladder.  A 
person  may  experience  a  strong  and 
sudden urge to go to the toilet but are 
not always able to hold on, or must go 
so 

frequently 

that 

it 

becomes 

inconvenient. 

Mixed Incontinence

 

Is  a  combination  of  both  Stress  and 
Urge Incontinence. 

 

Chronic Pelvic Pain 

Pelvic  pain  can  be  due  to  several 
causes such as: 

Vulvodynia, 

Symphysis 

Pubis, 

or 

Interstitial Cystitis. 

 

 

6. 

HOW ‘EMS’ WORKS 

E.M.S.  stands  for  Electrical  Muscle 
Stimulation and has successfully been 
used  in  medical  rehabilitation  and 
training  in  competitive  sports.  EMS 
produces 

intensive 

and 

effective 

muscular contraction. 

  

In  rehabilitation,  EMS  is  a  well-
established  method  for  treatment  of  a 
broad 

field 

of 

musculoskeletal 

diagnoses  as  well  as  pelvic  floor 
weakness.  Electrical  stimulation  of  an 
intact  peripheral  nervous  system  may 
create motor responses in patients with 
impaired  or  lost  ability  for  voluntary 
muscle activity. 

 

EMS is a complement to other physical 
therapy 

and 

should 

always 

be 

combined  with  active  training  such  as 
Kegel exercises (see section 4.2.). 

 

Advantages of EMS 

Use of EMS may lead to faster progress 
in  the  patient’s  treatment  programme. 
The  method  is  simple  and  appropriate 
for  treatment  in  the  clinical  setting  as 
well as for self-treatment at home.  

 

How EMS Works 

Electrical Muscle Stimulators can play a 
vital role in educating women and men 
about  their  pelvic  floor  and  the 
sensation they should feel when doing 
pelvic  floor  exercises.  Electrical  Pelvic 
Floor  Exercisers  (PFE)  offer  a  non-
invasive 

method 

of 

producing 

contraction  of  muscles  via  a  gentle 
stimulation to the pelvic floor through a 
discreet probe or electrode pads when 

Содержание Perfect PFE

Страница 1: ...0 INSTRUCTIONS FOR USE READ CAREFULLY BEFORE USE...

Страница 2: ...ert the vaginal probe Press and hold the ON button to switch the device on Regulate the output intensity with the buttons and Press and hold the OFF button to switch the device off ON Button P UP DOWN...

Страница 3: ...y tested products for the applications in the areas of gentle electrotherapy muscle toning continence management and pain relief during labour Please read these instructions for use carefully and keep...

Страница 4: ...GRAMMES 15 11 CONTENT 16 12 UNIT INFORMATION 17 12 1 CONTROLS DISPLAY 17 12 2 OPERATING INSTRUCTIONS 18 13 SETTING UP AND USING THE PERFECT PFE 20 13 1 INSTALLATION OF BATTERIES 20 13 2 CONNECTING LEA...

Страница 5: ...ue number so that the device can be identified This medical device is not water resistant and should be protected from liquids Atmospheric Pressure indicates the atmospheric limits to which the medica...

Страница 6: ...ectly complements pelvic floor exercises The perfect PFE is very easy to use with four clearly labelled preset training programmes a fifth programme for chronic pelvic pain and a simple push button co...

Страница 7: ...h to zero and flashes LEADS if the connection comes loose Automatic Keypad Lock Automatic keypad lock prevents any accidental changes in settings Large LCD Screen Clearly shows the operation of the un...

Страница 8: ...as a bulge in the vagina or a feeling of heaviness discomfort pulling dragging or dropping This occurs when one or more of the pelvic organs bladder bowel or uterus become displaced and sag down into...

Страница 9: ...g the muscles you identified earlier don t tense the muscles in your legs stomach or buttocks and remember to breathe normally 4 Aim to hold each squeeze or contraction for three to five seconds then...

Страница 10: ...in medical rehabilitation and training in competitive sports EMS produces intensive and effective muscular contraction In rehabilitation EMS is a well established method for treatment of a broad field...

Страница 11: ...ion medium frequencies 20 50 Hz can put a high level of strain on the muscle thus promoting the muscular structure Each preset programme has a specific frequency and pulse width that will offer the be...

Страница 12: ...sis see Ova cystitis sports injuries Raynaud disease fibromyalgia and neuralgia plantar fasciitis post operative pain and sometimes non painful conditions such as tiredness insomnia travel sickness ti...

Страница 13: ...ofessional before use Do NOT use when driving operating machinery or similar actions needing muscular control Loose electrode pads damaged leads or sudden changes in contact may cause brief involuntar...

Страница 14: ...unless the control unit is powered OFF as insertion or removal when stimulation is active may cause discomfort or tissue irritation Caution If tissue irritation occurs discontinue treatment immediate...

Страница 15: ...ay affect the sockets or cause the battery connector to develop a bad contact Caution Temperature Relative Humidity of storage 20 C 40 C 8 70 R H Temperature Relative Humidity of transportation 20 C 4...

Страница 16: ...t starts becoming apparent after about four weeks The sensation is like a strong drawing in of the muscles of the vagina pulling up the pelvic floor Your natural reaction will be to pull your muscles...

Страница 17: ...ng the TONE programme is a mixture of a strong drawing in of the muscles and then releasing A strong and fit pelvic floor may increase sexual health and enjoyment PAIN Shown on the screen as PAIN The...

Страница 18: ...TION 12 1 CONTROLS DISPLAY Programme selected Programme selector Time selector OFF button ON button Keypad Lock Programme duration min Strength selected mA Strength up Strength down Low Battery Output...

Страница 19: ...unit will remain in the WORK part of the cycle for 5 seconds while intensity is being adjusted The strength levels are shown on the LCD The strength control buttons will not operate until the unit is...

Страница 20: ...unlock press and hold the strength down control button LEADS ALARM The perfect PFE monitors the connection and the contact between you and the probe or the pads This is to prevent sudden changes if a...

Страница 21: ...nit is unlikely to be used for a long period Some types of batteries may leak corrosive fluid Battery Life Batteries should last about 18 hours at full power Unused batteries have a nominal shelf life...

Страница 22: ...rientation makes no difference and you can ignore this colour coding 13 3 PREPARING FOR SESSION 1 Before using perfect PFE you will need to visit the toilet 2 Lubricate the metal electrode surfaces an...

Страница 23: ...ed P in the centre of the control unit keypad 3 With the required programme selected you can adjust the intensity of the muscle stimulation until you reach a comfortable level Once you have reached a...

Страница 24: ...strength display on the control unit will reduce to 0 and flash during the rest period The URGE and PAIN programmes work differently There is no need to have a contraction The strength should be comfo...

Страница 25: ...be restricted to one muscle group and the mucosal tissue has different electrical characteristics anal stimulation is less comfortable than vaginal You should consult your healthcare professional bef...

Страница 26: ...d otherwise by a healthcare professional 5 Anal probes with long electrodes the metal part that run up and down the length of the attachment should always be inserted with the metal parts facing hip t...

Страница 27: ...label from our website www tenscare co uk attach this to an envelope or padded bag with the unit enclosed and post it back to us Upon receipt we will process your old device for components recovery a...

Страница 28: ...e from manufacturing defects for 2 years from date of purchase This warranty is void if the product is modified or altered is subject to misuse or abuse damaged in transit lack of responsible care is...

Страница 29: ...chase receipt Please ensure all relevant details are completed before sending your unit in for service Please ensure your contact details are still current and include a brief description of the probl...

Страница 30: ...ill also prevent anyone from increasing the intensity to a high level without firm contact between the machine and the skin A connection error can occur if 1 A break has developed within one of the tw...

Страница 31: ...appen in childbirth or some surgical procedures Please consult your healthcare professional No sensation on one side of the probe or electrode Position is not optimal needs adjusting The current flows...

Страница 32: ...g Atmospheric pressure 700hPa to 1060hPa Temperature range 25 70 C Humidity Up to 93 RH non condensing Atmospheric pressure 700hPa to 1060hPa TYPE BF EQUIPMENT Equipment providing a degree of protecti...

Страница 33: ...ANTY NAME ADDRESS POSTCODE DAYTIME TELEPHONE E MAIL MODEL DATE OF PURCHASE ATTACH PROOF OF PURCHASE DO NOT SEND IN PROBE OR ELECTRODE PADS RETAILERS NAME RETAILERS ADDRESS RETAILERS POSTCODE BRIEF DES...

Страница 34: ...33 NOTES...

Страница 35: ...e limited https plus google com TenscareLtdEpsom https uk pinterest com TensCareLtd https tenscareltd wordpress com https www youtube com channel UCzpik9dmLlJ3j0aHOpQ 0sg EC Declaration of Conformity...

Страница 36: ...35 Distributed by Manufactured by TensCare Ltd 9 Blenheim Road Epsom Surrey KT19 9BE UK Tel 44 0 1372 723434 www tenscare co uk Pub No I PPFE UK Version 2 2 05 17...

Отзывы: