MAINTENANCE
38
Tennant T600 EE (04-2018)
TROUBLESHOOTING - Continued
PROBLEM
CAUSE
SOLUTION
Little or no solution flow
Empty solution tank
Refill solution tank
Low solution flow rate set
Increase solution flow rate
Clogged solution tank filter
Clean filter
Plugged solution supply line
Flush solution supply line
Short run time
Low battery charge
Charge batteries
Batteries need maintenance
See BATTERIES
Defective battery or end of battery life
Replace batteries
Battery discharge indicator (BDI)
programmed incorrectly
See CHARGING BATTERIES
Faulty charger
Replace battery charger
Brush pressure set too high
Lower brush pressure
Solution tank auto-fill
does not function
properly
Coupler not properly connected
Connect coupler
Faulty shut-off float
Replace float. Contact service
Machine not on level surface
Machine must be on level surface