WHILE OPERATING MACHINE
WARNING: Flammable materials or reactive
metals can cause an explosion or fire. Do not pick
up.
1. Overlap each scrub path by 2 inches/5 cm.
2. Keep machine moving to prevent damage to floor
finish.
FOR SAFETY: When operating machine, the
machine may only be operated on gradients up to
2%.
3. Raise scrub head when approaching bumps such
as floor transitions and thresholds. If bump height
exceeds a half inch (1.27cm) remove scrub disks
from machine.
4. Reduce speed around turns, near crossings, and
approaching tight areas, etc.
5. Avoid bumping the machine into posts and walls.
6. Wipe squeegee blades with a cloth if blades leave
streaks.
7. Pour a recommended foam control solution into the
recovery tank if excessive foam appears.
ATTENTION:
Foam buildup will not activate the
float shut-off screen, vacuum motor damage will
result.
8. Use the double scrubbing method for heavily soiled
areas. First scrub the area with the squeegee up,
let solution set for 3-5 minutes, then scrub the area
a second time with squeegee down.
9. When leaving the machine unattended, park on
level surface, turn machine off and remove key.
FOR SAFETY: Before leaving machine, stop on
level surface, turn off machine and remove key.
10. Do not operate machine in areas where the
ambient temperature is above 110ºF/43ºC or below
36ºF/2ºC.
11. If machine becomes disable, it can be pushed as
described in the PUSHING AND TRANSPORTING
MACHINE section.
CIRCUIT BREAKER PANEL
The machine is equipped with resettable circuit
breakers to protect the machine from a current
overload. If a circuit breaker trips, unplug the battery
cable connector and reset the breaker by pressing the
reset button after the breaker has cooled down.
Reconnect the battery cable connection. If the circuit
breaker does not reset or continues to trip contact
service personnel.
The circuit breaker panel is located below the control
console. The circuit breakers are identified as
described below (Figure 39).
FIG. 39
Circuit
Breaker
Rating
Circuit protected
CB1
2.5 A
Key switch circuit
CB2
10 A
Control board
CB4
40 A
Propel
FOR SAFETY: When servicing machine, all repairs
must be performed by trained personnel.