MAINTENANCE
21
443C MM294 (12–91)
3. Grasp the end of the squeegee blade(s) that
need replacing and pull it sideways out of
the blade retainer. Use a dry cloth to grasp
the squeegee blade if needed.
A
B
06632
REMOVING SQUEEGEE BLADE
A. Squeegee Blade
B. Scrub Head
4. Lubricate new squeegee blade in
water/detergent from tank. Pull new
squeegee blade into the scrub head blade
retainer until it is centered in the scrub head.
Use a dry cloth if needed to grip squeegee
while pulling it into retainer.
5. If all the squeegees need to be replace,
remove the scrub head assembly from the
machine.
6. Pull out any squeegee blades that need
replacing.
A
B
06246
REMOVE SQUEEGEE BLADE
A. Squeegee Blade
B. Scrub Head
NOTE: Use a dry cloth to help get a grip on the
squeegee blade end to pull the blade out of the
scrub head.
7. Pull the new squeegee blade into the scrub
head from the blades end until the blade is
centered in the scrub head.
NOTE: Lubricate the new squeegee blade with
some detergent to make pulling the blade into the
scrub head much easier. Use a dry cloth to help
get a grip on the squeegee blade end to pull the
blade out of the scrub head.
8. Flush out the scrub head assembly and
install it back on the machine.
STORAGE INFORMATION
Freeze protection of the machine is necessary to
prevent damage to components of the solution
system when the machine is going to be exposed
to freezing temperatures.
ATTENTION: Freezing temperatures can
severely damage components. Do not store or
transport machine in areas where freezing of
solution contents could occur, unless
machine is freeze protected. Failure of
components due to lack of freeze protection
voids the warranty on such components.
FREEZE PROTECTION
1. Pour 1 gal (3.8 L) of pre-mixed
automotive-type windshield washer solution
into solution tank.
ATTENTION: Do not use cooling system
anti-freeze such as ethylene glycol.
2. Move machine over floor drain and plug the
power cord into an outlet.
3. Set the MODE switch in the WAND position.
The pump will start and spray through the
feed tube to the floor. Run in this manner
until all of the solution is dispensed.
ATTENTION: Machines and attachments that
have been freeze protected must be flushed
completely prior to normal use. Follow
directions for the appropriate cleaning
process, but run your selected cleaning
solution through the system to purge all
anti-freeze before starting the cleaning
process.