OPERATION
443C MM294 (10–91)
12
6. Pull the vacuum inlet filter out of the side of
the fill area and rinse the filter with clean
warm water. Push the inlet filter back into
the fill area making sure the screen is facing
down into the tank.
B
A
06226
VACUUM INLET FILTER
A. Fill Area
B. Vacuum Inlet Filter
7. When the solution tank is completely
drained and flushed, place the drain plug
back into the end of the drain hose and turn
the end of the drain plug to the right to
tighten the plug. Place the drain hose back
into the retaining clip on the back of the
machine.
POST-OPERATION CHECKLIST
Check this list of items over after operating the
machine:
Check power cord for wear or damage.
Repair or replace if required. Wipe cord
clean and wrap around the machine
handles.
Raise the scrub head by stepping on the
scrub head lift lever.
Flush squeegee housing with hot water,
especially if the machine is used in greasy
areas.
Wipe grease/debris build-up from squeegee
and squeegee nozzles.
Check for and remove any string or material
wrapped around the scrub brush.
Check the solution dispensing tube for any
plugged holes.
Check the squeegees for wear or any
damage. Replace any worn or damaged
squeegees.
Push the machine to an area to be kept until
it is needed again. Be sure the scrub head is
raised.
Freeze protect machine if it will be stored or
transported in areas where solution in the
system may freeze and damage the
components. See FREEZE PROTECTION
under STORAGE INFORMATION.