member in pump casing
cavity (figure 5.1J). Be
certain the stationary seal
member is fully squared
and seated in cavity.
14.
Slide the rotating member
onto the lubricated pump
shaft (figure 5.1K). Be
certain not to damage or
tear the rubber bellows
assembly.
15.
Place the spring onto the
rotating member.
16.
Align the tension spring
and rotating member before
reinstalling the impeller
(figure 5.1L). Be certain the
spring and rotating member
are aligned before the
impeller is fully tightened
and the impeller retaining
screw is reinstalled.
17.
Clean the pump casing,
cavities, impeller and
O-ring before reassembly.
18.
Mate the motor and
adapter to the pump
casing. Reinstall the 4
pump casing bolts.
19.
Reconnect the motor power
cord and leads.
20.
Replace the thermoformed
front panel and the lift-off
cover.
E.
When this procedure is complete,
the operator may restart the unit.
In many cases, a new pump seal
will experience a small amount of
leakage for a short time. This is
normal. After a few moments, the
new seal will take seat and the leak
will stop.
5.2
HEATER REPLACEMENT
Seal components
Figure 5.1I
Stationary member
Figure 5.1J
Rotating member
Figure 5.1K
Aligning impeller and spring
Figure 5.1L
Содержание VETERAN LS Series
Страница 2: ......
Страница 8: ...Page 8 THIS PAGE INTENTIONALLY BLANK ...
Страница 60: ...Page 60 THIS PAGE INTENTIONALLY BLANK ...
Страница 68: ...Page 68 THIS PAGE INTENTIONALLY BLANK ...
Страница 78: ...Page 78 THIS PAGE INTENTIONALLY BLANK ...
Страница 79: ...END 2013 Temptek INC RE 1 02 13 ...
Страница 80: ......