Mounting Hardware Options
Mounting Bolts
1.
DO NOT DISCARD THE BOLTS ATTACHING THE
ENCLOSURE TO THE SHIPPING PALLET
2.
Each Enclosure must be mounted with FOUR points.
3.
Mountings must be made using M12 or ½” bolts
4.
Tempest recommends the use of stainless steel
mounting hardware.
5.
Bolt enclosure to a stable structure capable of
supporting the weight of the enclosure plus the
luminaire enclosed.
Globe Down Tornado Enclosures
6.
Bolt the Tornado enclosure to a suitable overhead
structure using the bolts and Unistrut spring nuts
supplied
7.
To hang from a lighting truss, use four hanging clamps
or half-couplers, bolted to Unistrut spring nuts
8.
Screw the eyebolts supplied into the center threaded
holes in the Unistruts and secure to the overhead
structure or truss with a safety cable (not supplied)
rated for 5 x the total weight of the Tornado enclosure
plus luminaire.
Horizontal Tornado Enclosures
9.
Bolt the Tornado enclosure to a suitable overhead
structure using the bolts and Unistrut spring nuts
supplied – see illustration (6).
IMPORTANT SAFETY NOTICE
Installer must ensure that all mounting points are secure
and conform to local safety regulations. Tempest Lighting
Inc. accepts no responsibility for damage or injury arising
from inappropriate or unsafe installation.
M12-1.75 x 40 bolts,
washers, nuts
DO NOT DISCARD!
NOTE:
Globe Down and
Horizontal enclosures
also supplied with
Unistrut Spring nuts.
Use the M12 bolts,
washers and Unistrut
spring nuts provided to
attach globe-down
Tornado enclosures to a
suitable overhead
support.
Attach hanging
clamps or half
couplers to the
Unistrut rails to
hang Tornado from
a lighting truss
Safety cable Eyebolts