For single feed wiring, no modification to the DEC4
Controller motherboard is needed.
IMPORTANT:
For split feed wiring, use a side cutter to cut both AC links at both
ends:
Single Feed Power Termination
Connect Earth/Ground wire to Ground Terminal
Connect Live and Neutral to the terminals marked
FEED
Split Feed Power Termination
STOP! Did you cut the power links? See above.
Connect Earth/Ground wire to Ground Terminal
Connect Enclosure feed to the terminals marked FEED
Connect Luminaire feed to the terminals marked SPLIT
SEE WIRING DIAGRAMS BELOW
AC Supply Voltage
Tempest Tornado enclosures require supply voltage in
the nominal range 200-250VAC, 50/60Hz.
North American installations – use a 208V
supply (2 x 120V hots), and connect one hot to
Line and one to Neutral terminals.
North American 120V versions are available to
special order.