Tornado G4 User Manual
15
Identify the following parts:
AC Terminal Block
Earth/Ground Terminal
DEC4 Motherboard
DEC4 Daughter Board(s)
Up to 3 daughter boards: types include Fan Control,
RS485 Comms, Ethernet
(CUTAWAY VIEW)
One or Two Power Circuits?
Tempest enclosures may be wired on single or double
circuit supplies. On a single feed, both enclosure and
luminaire are permanently on. With a split (double) feed
supply, you can switch off the luminaire when not in use,
while the enclosure continues to protect it 24/7.
Tip: most people use single feed.
Tip: even wired for single feed, you can use DMX to switch
the luminaire power on and off – see the DEC4 section
below.
Single Feed
Enclosure and luminaire are permanently on.
Enclosure and Luminaire must be rated for the
same voltage.
Supply must be rated for luminaire current plus
150 watts.
Supply must be permanently ON.
Split feed
Enclosure power must be permanently ON.
Luminaire power may be switched off.
Enclosure power must be rated for:
o
Tornado 1850-1975: 650 watts
o
Tornado 2000-2300: 1150 watts
o
Tornado 2400-2500: 2000 watts
Luminaire power must be rated for the luminaire (see
luminaire manual).
Single Feed
Split Feed