Blizzard G4 User Manual
34
Reset Lamp Hours
Reset each time you change the lamp in the projector.
Make this a part of your maintenance instructions.
Set Fan Function
SET FAN TEST
To test the enclosure fan(s), press [OK]
The enclosure fan will run
The Display Fan LED lights green
DEC Beeps
To stop the fan test, press [ESC]
Status Display
View current status information, using the arrow keys to scroll through:
a)
Humidity – relative humidity in %
b)
Internal temperature, in degrees C or F
c)
External Temperature (custom enclosures with external temperature sensors only)
d)
PCB temperature (this will usually be significantly higher than air temperature)
e)
Voltage – line Voltage reaching the DEC
f)
Current being drawn by projector/light, in Amps
g)
Lamp Hours elapsed since last reset
h)
Firmware version
i)
UID – unique system ID number