Installation 

 

Dimensions, Rigging Points, and Maximum Projector Dimensions/Power 

 

Model 

Format 

DIM A 

DIM B 

DIM C 

DIM D 

DIM E 

Weight 

Projector Max: 
Size (LWH) * 

Projector 
Max Power 

52.050 

Landscape 

737 
29in 

660 
26in 

343 
13.5in 

660 
26in 

584 
23in 

27kg 
59lb 

610x520x225 
24x20.5x9in 

800W 

52.050P 

Portrait 

737 
29in 

432 
17in 

584 
23in 

660 
26in 

356 
14in 

30kg 
65lb 

595x520x225 
23.5x20.5x9in 

800W 

52.050U 

Short Throw 

tbd* 

tbd* 

tbd* 

tbd* 

tbd* 

tbd* 

tbd* 

800W 

52.100 

Landscape 

864 
34in 

762 
30in 

368 
14.5in 

787 
31in 

686 
27in 

32kg 
70lb 

695x595x275 
27.5x23.5x11in 

1,200W 

52.100P 

Portrait 

864 
34in 

432 
17in 

686 
27in 

787 
31in 

356 
14in 

36kg 
78lb 

695x595x275 
27.5x23.5x11in 

1,200W 

52.100U 

Short Throw 

tbd* 

tbd* 

tbd* 

tbd* 

tbd* 

tbd* 

tbd* 

1,200W 

52.150 

Landscape 

1067 
42in 

762 
30in 

419 
16.5 

991 
39in 

686 
27in 

42kg 
92lb 

1095x595x355 
41.5x23.5x14in 

1,800W 

52.150P 

Portrait 

1067 
42in 

483 
19in 

762 
30in 

991 
39in 

406 
16in 

47kg 
104lb 

1095x595x355 
41.5x23.5x14in 

1,800W 

52.150U 

Short Throw 

tbd* 

tbd* 

tbd* 

tbd* 

tbd* 

tbd* 

tbd* 

1,800W 

 

 

*tbd – please consult factory 

 

Note: Be sure to allow for the length of the lens and for connectors, cables and 
cable bend radii when calculating dimensions 

Rigging Points: 

M10-1.5 threaded holes at 
each corner, top and 
bottom. 

Note: 8 x M10x40 stainless 
steel bolts supplied 

Содержание 52.050P

Страница 1: ...Blizzard G4 User Manual 1 User Manual Blizzard G4 Revision 02 1 September 2017 Tempest Lighting Inc...

Страница 2: ...Kit 12 Mounting Options Desert Filter Baffle 13 Wiring the Enclosure 14 Power Wiring 14 SAFETY NOTICE 14 Electrical Standards 14 Wiring Access 14 One or Two Power Circuits 15 Conduit Entries 16 Single...

Страница 3: ...r Interface LCD Display 31 Control Interface Operation 31 Control Menu 32 Set Data Options 32 Set Temp Units 33 Set Temp Ranges 33 Set Max Humidity 33 Set Lamp On Point 33 Reset Lamp Hours 34 Set Fan...

Страница 4: ...ical and UL 50 environmental as NEMA 3R enclosures for use in the United States and Canada This declaration is made by the manufacturer Tempest Lighting Inc 11845 Wicks Street Sun Valley CA 91352 USA...

Страница 5: ...EU Directives Low Voltage Directive 2006 95 EC Test Report G4 51 LVD Electromagnetic Compatibility Directive 2004 108 EC Test Report G4 51 EMC and further conforms with the following EU Harmonized St...

Страница 6: ...Blizzard G4 User Manual 6 Approvals China...

Страница 7: ...s Lifting some enclosures and the equipment inside them may be heavy Use properly rated lifting equipment where appropriate and never attempt to carry out work with fewer than the number of workers ne...

Страница 8: ...95x595x275 27 5x23 5x11in 1 200W 52 100P Portrait 864 34in 432 17in 686 27in 787 31in 356 14in 36kg 78lb 695x595x275 27 5x23 5x11in 1 200W 52 100U Short Throw tbd tbd tbd tbd tbd tbd tbd 1 200W 52 150...

Страница 9: ...um clearances shown around your enclosure Snow Clearance In areas where snow is likely make sure the base of the enclosure is at least 24 60cm above highest potential snow drift level Allow 1m 3ft for...

Страница 10: ...st 75mm 3in clearance below IMPORTANT SAFETY NOTICES Installer must ensure that all mounting points are secure and conform to local safety regulations Tempest Lighting Inc accepts no responsibility fo...

Страница 11: ...ut Rail kit is required for use of Blizzard enclosures with the Cyclovator tilt kit Mounting Options Cyclovator Cyclovator allows you to mount up to two Blizzard 100 or 150 enclosures and tilt them up...

Страница 12: ...end hanging Blizzard 150 models from a single vertical pole due to size and weight considerations Use two vertical poles join together with a horizontal pipe and use the Horizontal Pole Hanger kit abo...

Страница 13: ...ast their way through it and allow fine particles to enter the enclosure 51 DFB 11 Blizzard 52 050 L xx 52 100 L xx 51 DFB 15 Blizzard 52 150 L xx For other Blizzard models consult factory Remove the...

Страница 14: ...arising from failure to observe this requirement Electrical Standards Important Enclosure model numbers ending US are for use in countries using US and Japanese style electrical systems 100 120VAC 50...

Страница 15: ...ed on single or double circuit supplies On a single feed both enclosure and projector are permanently on With a split double feed supply you can switch off the projector when not in use while the encl...

Страница 16: ...ries Two conduit entry holes are provided sized for PG21 US conduit or cable glands Use one for power and the other for signal cables DO NOT run power and signal cables through the same conduit IMPORT...

Страница 17: ...Feed Power Termination STOP Did you cut the power links See above Connect Earth Ground wire to Ground Terminal Connect Enclosure feed to the terminals marked FEED Connect Projector feed to the termin...

Страница 18: ...standard equipment included 3 Grouped via RS485 using an Ethernet bridge and Tempest TEMP protocol Requires one 51 485 RS485 board per enclosure standard equipment included Note Tempest System Manager...

Страница 19: ...g 52 100 LF US Fixed projector mount 52 150 PS IN Sliding projector mount Using either Fixed or Slide mounts you can access the projector from either side and also from the back for relamping rear acc...

Страница 20: ...ess to the projector bridge clamp screws 2 Using a 2 Philips screwdriver loosen the projector bridge clamp screws until they are no longer engaged in the projector bridge clamps 3 Repeat on the other...

Страница 21: ...over by removing the M4 nut using a 7mm nut driver 4 Remove the six M4 nuts attaching each of the projector beams to the enclosure base using a 7mm nut driver 5 Lift the projector beams and bridges ou...

Страница 22: ...nd unscrewing from the projector bridges 4 Slide the projector along the projector bridges so that it is roughly centered in the enclosure 5 Replace the projector rods nearest you 6 Align the projecto...

Страница 23: ...projector power cable into one of the IEC C13 outlets provided THE PROJECTOR MUST BE POWERED THROUGH THE DEC 6 The second outlet is available for any auxiliary equipment that may be housed inside the...

Страница 24: ...the projector being used and include a mounting bracket with screws and holes aligned to the threaded holes in the projector base Portrait enclosures are also available with fixed or sliding projector...

Страница 25: ...cified by the user 1 Remove the two safety knobs 2 Loosen do not remove the four mounting bolts 3 Slide the mounting tray forward away from the cover hinge and remove 4 Attach the projector to the mou...

Страница 26: ...er of outdoor equipment DEC4 monitors internal and external temperature humidity and lamp current at all times and uses this information to control the enclosure s lamp relay fan s and heater s It can...

Страница 27: ...rojector Luminaire current Line Voltage External Temperature Internal Temperature Internal Relative Humidity DEC 3 3 s patented GoldilocksTM algorithm uses a combination of sensors heaters and fans to...

Страница 28: ...hard reset of the lamp relay in the event of a projector malfunction RDM Status Reporting over RS485 RDM Configuration settings may be changed remotely or at the enclosure user interface Control mode...

Страница 29: ...her than those around the projector 2 We recommend using the factory default settings for several weeks or months before making any changes In most cases they will not be necessary Trip Temp 55 70 C D...

Страница 30: ...running Lamp Relay ON Green Lamp relay is closed normal Projector power receptacle is energized ON Red Lamp relay is open due to over temperature event Projector power receptacle is isolated Temp FLAS...

Страница 31: ...erface Operation The Control Interface is normally LOCKED To UNLOCK hold ESC and OK together for 5 seconds You are now in the CONTROL MENU Use to scroll up and down the menu Press OK to enter a menu i...

Страница 32: ...vice modes Select a DMX starting address in the range 001 to 510 1 Lamp Relay In Service Mode an addition two slots are available 2 Fan Duty Control 3 Heater Duty Control Note that the DMX control is...

Страница 33: ...ch load will be isolated see note default 60 C permissible range 55 70 C Note A thermal emergency is when enclosure ventilation fails with the lamp on in which case the temperature will rise very quic...

Страница 34: ...press ESC Status Display View current status information using the arrow keys to scroll through a Humidity relative humidity in b Internal temperature in degrees C or F c External Temperature custom e...

Страница 35: ...ating RS485 Board 51 485 firmware may be updated over an RDM network using JESE GETSET software and a JESE RDM TRI interface All required files are available for download at http www tempest biz tech...

Страница 36: ...or non Unicode programs is set to a non Asian language 3 Plug you RDM TRI in to your PC 4 Power up the target SCB ideally with mains power or alternatively with a USB power adaptor connected to the US...

Страница 37: ...ption Select the data mode from the DEC user display 7 Open the GetSet application connect to the RDM TRI and discover the DEC To run discovery click the Icon indicated below 8 Right click on the high...

Страница 38: ...andler search for a file to upload by clicking the file icon Find and select the file to load and click the Open button 10 On returning to the File upload tool window select the green upload arrow to...

Страница 39: ...cation and disconnect the USB Cable from the SCB Important If the Tempest enclosures are connected to an RDM interface or controller set the DATA MODE for each enclosure as follows RDM MONITOR ONLY To...

Страница 40: ...ure inside the enclosure will start to rise This is an indication that the filter must be changed Part Numbers 51 HF 11 Blizzard 050 100 Replacement Filter 51 HF 15 Blizzard 150 Replacement Filter To...

Страница 41: ...above the port glass is defective the controller may not operate correctly A defective sensor will result in one of three messages appearing on the DEC user interface If you see any of these messages...

Страница 42: ...ebris inside enclosure 1 Filter is either missing or damaged 2 Filter is not properly seated 3 Side panels or back door is not firmly latched Water in enclosure 1 Check the drain holes in the bottom o...

Страница 43: ...above ii to any Goods that have been subject to misuse abnormal service or handling or altered or modified in design or construction iii to any Goods repaired or serviced by any person other than Sell...

Страница 44: ...d and monitored over an IP network Please contact factory for ordering information Physical Layer 1 EITHER Use a 51 EN Ethernet daughter board plugged directly to the DEC4 motherboard connected to you...

Отзывы: