background image

Input Guard 

 Models VM500-6, VM500-6-LV, VM500-6-HV 

For units purchased on or after August 10, 2002 

Manual and Installation Instructions 

Содержание Input Guard VM500-6

Страница 1: ...Input Guard Models VM500 6 VM500 6 LV VM500 6 HV For units purchased on or after August 10 2002 Manual and Installation Instructions...

Страница 2: ...ming Reminder Calls 10 Using the Input Guard 12 How does in input go into alarm condition 12 What happens when an input is in alarm condition 12 How do I activate the on board relay R only 12 What hap...

Страница 3: ...bers The Input Guard also monitors the power to which it is con nected and will calls its programmed numbers if a power outage exists For models with the A option The Input Guard will turn on its alar...

Страница 4: ...4 Wiring diagram 1...

Страница 5: ...f which you want monitored 4 Connect the wall mount transformer power jack to the Input Guard on the top of the unit 5 For ease of wiring remove the terminal blocks 6 Wire each input to the terminal b...

Страница 6: ...n off relay R option only 0 Hang Up Programming Input Parameters Each input can be programmed to be either a normally closed or normally open input Each input has its own time delay for which the inpu...

Страница 7: ...other button to not change the message If you do not press one go to step 19 15 You will hear a tone 16 Begin speaking after the tone The Input Guard will record for about 4 seconds 17 After 4 seconds...

Страница 8: ...l pager number 1 area code if necessary followed by the key 4 You will hear the telephone number you just entered 5 You will be automatically returned to the Program Menu Note If an extra delay betwee...

Страница 9: ...programmed number 4 You will hear Press one to change 5 Press 1 if you wish to make a change or press any other button to return to the Program Menu 6 You will hear Enter number then press pound 7 En...

Страница 10: ...automatically returned to the Program Menu Programming the PIN Number The Input Guard uses a 4 digit PIN number 0000 9999 to identify you when calling the device or during callout procedures After pro...

Страница 11: ...o enable Reminder Calls 4 You will hear Reminder Call is On Delay is 6 0 minutes press One to Change 5 Press 1 to set a custom time delay for the reminder call 6 You will hear Enter number then press...

Страница 12: ...making emergency phone calls Pushing the white Alarm Off button on the face of the Input Guard will cause the alarm buzzer to turn off and the alarm relay to de energize After the Alarm Off button ha...

Страница 13: ...he user ID 10100000 would indicate inputs 1 and 3 are on and the last 1 indicates power is on The Input Guard will continue to make calls until either The alarm condition goes away OR The Input Guard...

Страница 14: ...xample A fax machine on the same line as the Input Guard is set to answer after 4 rings The Input Guard is programmed to answer after 5 rings To access the Input Guard dial the number let it ring thre...

Страница 15: ...securely Verify that the Input Guard is powered up and the status light is blinking If the Input Guard does not call out Verify that the phone line is good Connect a phone to the line intended for th...

Страница 16: ...is telephone equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practi...

Страница 17: ...location and someone verifying the proper response This warranty shall terminate and be of no further effect at the time the Product is 1 damaged by extraneous causes such as fire water lightning etc...

Страница 18: ...Microtechnologies Inc 564 Wilbur Cross Highway Berlin CT 06907 1 860 829 2710 ph 1 860 829 2712 fax www TemperatureGuard com sales TemperatureGuard com Rev 8 10 02...

Отзывы: