TEMA TELECOMUNICAZIONI SRL
Doorphone AA-514
MAS-AA514-REV03EN
Page 40 of 56
9.4.
Parameters table
In the following table are described the system parameters. All the values will be retained even if the system is
powered off.
Parameter
Name
Description
Range = possible values
Default
Enter your
settings
153 #
Expansion type
Set AA-514 expansion used
0 = no expansion
1 = expansion model AA-514P
2 = expansion model AA-516K
Range: 1 digit, values 0-2
0
118 #
Operation mode of
buttons
Set the operating mode
0 = DAY/NIGHT mode (see parameters 121/122)
1 = GROUP mode
2 = DAY/NIGHT mode with repetition call
Range: 1 digit, values 0-2
0
101 #
Max conversation
time
Maximum call duration time in seconds, for inbound and
outbound call.
Range: max 4 digits, values 10-9999
60
110 #
Telephone number
Button 1 in
DAY mode
Telephone number associated to the Button 1 in Day mode
or Group1 mode.
Range: max 16 characters, values 0-9, *
* = pause of 0.5 seconds
9
111 #
Telephone number
Button 2 in
DAY mode
Same as parameter 110 but for the Button 2
--
112 #
Telephone number
Button 3 in
DAY mode
Same as parameter 110 but for the Button 3
--
113 #
Telephone number
Button 4 in
DAY mode
Same as parameter 110 but for the Button 4
--
114 #
Telephone number
Button 1 in
NIGHT mode
Telephone number associated to the Button 1 in Night mode
or Group2 mode.
Range: max 16 characters, values 0-9, *
* = pause of 0.5 seconds
9
115 #
Telephone number
Button 2 in
NIGHT mode
Same as parameter 114 but for the Button 2
--
116 #
Telephone number
Button 3 in
NIGHT mode
Same as parameter 114 but for the Button 3
--
117 #
Telephone number
Button 4 in
NIGHT mode
Same as parameter 114 but for the Button 4
--
220 #
Supervisor Number
Number of the supervisor. The supervisor is the person
called from AA-514 when it is programmed to work in Group
mode (parameter 118 value 1). This number will be called if it
is not received a reply from the numbers associated with the
Day and Night mode with the confirmation code response
(parameter 123). This number may be associated to a
guardian or to another available person.
Range: max 16 digits, values 0-9, *
* =pause of 0.5 seconds
-
119 #
Call closing
command
Command to hang up the current conversation to force the
system in standby mode. It may be equal to the open relay1
code (parameter 120).
Range: max 3 digits, values 0-999, #, *
#0
127 #
Conversation time
extension
Command to keep alive the current conversation resetting
the max conversation time at the value of parameter 101.
Range: 3 max digits, values 000-999, #, *
#5
123 #
Answer code
In the operation mode GROUP and D/N with repetition, it is
possible to signal to the system the successful reply from the
called telephone, by dialing the number programmed here
immediately after answering the call.
Range: max 1 digit, value 0-9
1