Level field and delta indicate a value level – when it exits or enters value +- delta/2, device
generates an event. I.e. to generate speeding event when speed reaches 80 km/h enter level value 40
and delta value 80. This would make low level of speed 0 km/h (40 – 80/2) and high level 80 km/h
(40 + 80/2). When current speed exits this range, event will be triggered. As alternative you can also
enter level 90 and delta 20. This would trigger event when speed becomes 80...100 km/h. Battery level
is measured in percentage, speeding measured in km/h, GSM level is measured in point with
maximum value of 5.
Average field is not currently in use and is reserved for future functionality.
•
Profile manager: managing between profiles is done via Profile Manager. Basically it is done
via logical sentences, which are collection of criteria encoded in 50 characters.
If external circumstances are identical to those stated in logical sentence, profile switching
occurs. There are four sentences: getting from first to fourth profile. Switching to fifth profile occurs
when there are no valid sentences which matches to IO events.
Figure 17. Profile manager window
Table 1. Legend of logical sentence parameters
Example of good logical sentence: MR1=0&{{CI1=1|GT1=0}^AI1<3000}