TP-8/16/24/32/64S User Manual Version No.: V1.2
- 67 -
The parameter is only “
-
3.5”, “
-
7” or “0”, unit is dB.
Command to set compressed chip package cycle
codec_ep1> pktintvl {parameter}
The parameter is the package cycle, unit is ms. For example:
codec_ep1> pktintvl 20
Coding priority setting command
Interaction setting mode:
codec_ep1> priority
Only “priority” command is entered, the command line will inquire the priority that user is going to
set, as shown below:
Algorithm priorities:
[1] G.711A G.711U G.729 G.723.1
[2] G.711U G.711A G.723.1 G.729
[3] G.729 G.711A G.711U G.723.1
[4] G.729 G.723.1 G.711A G.711U
[5] G.723.1 G.711A G.711U G.729
[6] G.723.1 G.729 G.711A G.711U
Input your choice[1~6]:
At this time it is only allowed to enter numbers from choice [1~6]. Users are able to press “Ctrl
+
C”
or directly button enter key to get out of priority setting status if driven by the intention to give up
setting.
Non-interaction setting method
codec_ep1> priority {parameter}
The parameter is only chosen from [1~6], which stands for the sequences of six coding priorities under
interaction method.
Setting command of value of RFC2833 payload type
codec_ep1> rfc2833_pt {parameter}
The parameter ranges from 96 ~ 127.
Ring time setting command
codec_ep1> ring {parameter1} {parameter2}
Parameter 1 is “on time”, namely the ring duration time; parameter 2 is “off time”, namely the ring
interval time. The parameters for the both range from 0
~
65535, unit is ms.
Command of mute compressed switch setting
codec_ep1> sc {parameter}
The parameter is only “enable” or “disable”. Therein, “enable” means to open the mute compressing