60
60
9 INACTIVITY
9.1 Keeping the machine efficient if it remains inactive
If the machine will not be used for a lengthy period, follow these instructions:
- Sanitise the machine as described in sec. 6.1.
- Switch off the machine using the I/O - ON/OFF button, power down at the mains master switch and take the
plug out of the socket.
If the machine that will be inactive is water-condensed, close the Water In tap and discharge the water pressure in the
delivery tube by unscrewing the end connector. Remove both the delivery tube and the drainage tube and empty the
water from them. Before using again after a long period of inactivity, check the connector gaskets for damage, substi-
tuting them if necessary.
BEFORE STORING A WATER-CONDENSED MACHINE IN ENVIRONMENTS WITH TEMPERATURES
BELOW 0°C, COMPLETELY EMPTY THE WATER FROM THE MACHINE COOLING SYSTEM, AS
IT COULD FREEZE INSIDE IT, CAUSING VERY SERIOUS DAMAGE.
If an air-condensed machine has been inactive, before switching it on remove dust from the condenser grilles “dry” with
a vacuum cleaner and, if necessary, a brush, so that the dust is removed outwards.
DO NOT USE LIQUIDS BECAUSE THEY WOULD FIX THE DUST ON THE CONDENSER.
REMOVE DUST FROM THE CONDENSER GRILLES OUTWARDS TO AVOID COMPROMISING
THE PERFORMANCE OF THE REFRIGERATION SYSTEM.