Removing the mixing impeller
–
Grip the mixing impeller (3) drive and pull it out vertically.
–
Extract the bushing (3A) from the the mixing impeller (3) drive.
Thoroughly clean the inside of the mixing impeller drive using the
tube brush supplied (F).
•
Removing the drip tray
–
Remove the drip tray (4) from the related supporting bracket
(5).
•
Removing the dispensing tap:
–
Turn the dispensing tap opening/closing lever (6) AN
-
TI-CLOCKWISE until it is vertical (OPEN position).
–
Loosen the knurled knob (7) and extract the dispensing tap
from the tank outlet (8).
–
Unscrew the opening/closing lever (6) and remove the tap
cover (9).
–
Take the piston (10) out of the tap body (11) horizontally.
–
Remove the gaskets (12-13-14) from their seats.
Thoroughly clean the inside of the tap body (11)
and the tank outlet using the tube brush supplied
(F).
4
5
4
7
6
7
8
6
9
10
11
10
11
12
13 14
11
F
3
F
3A