Deleting a user (also available with Admin role):
SMS command
Reply from device
Meaning of reply message
d=PHONE NUMBER,NAME#
or
d=,NAME#
or
d=PHONE NUMBER#
DELETE SUCCESFULL
User deleted successfully
DELETE FAILED, USER NOT
FOUND!
The given user name or phone
number does not exist in the system
SYNTAX ERROR!
Wrong command (
or # is missing,
or other typing error)
Deleting all users (also available with Admin role):
SMS command
Reply from device
Meaning of reply message
ERASEALLUSERS#
USERS ERASED!
All users deleted successfully
SYNTAX ERROR!
Wrong command (
or # is missing,
or other typing error)
Configuring the permitted entry period:
SMS command
Reply from device
Meaning of reply message
EP=FROM,TO#
Example:
EP=08:00,16:30#
ENTRY PERIOD CHANGED
Permitted entry period changed
successfully
SYNTAX ERROR!
Wrong command (
or # is missing,
or other typing error)
Command parameter values:
FROM:
permitted daily entry period start (hh:mm)
TO:
permitted daily entry period end (hh:mm).
Configuring the output control mode:
SMS command
Reply from device
Meaning of reply message
M=1,A=1,B=1#
M=2,A=1,B=1#
M=3,X=1,Y=1,W=15,Z=1,O=1#
M=4,X=1,Y=1,Z=1,O=1#
M=5,X=1,Z=1#
MODE
1
ACTIVATED
Control mode
1
. set successfully
SYNTAX ERROR!
Wrong command (
or # is missing,
or other typing error)
Command parameter values:
M=1
…
5
output control mode number
(1…5).
A=0
…
86400
OUT1 pulse length (seconds) =>
for opening gate “A”.
B=0
…
86400
OUT2 pulse length (seconds) =>
for opening gate “B”.
X=0
…
86400
OUT1 pulse length (seconds) => for gate opening.
W=0
…
86400
delay before interrupting the photocell loop (seconds).
Y=0
…
86400
For M=3: OUT2 pulse length (seconds) => for keeping the gate open.
For M=4: keep gate open duration (seconds) => for keeping the gate open.
Z=0
…
86400
OUT1 pulse length (seconds) => for gate closing.
O=0
…
1
keeping the gate locked in open state upon a second call:
O=1
function enabled
O=0
function disabled