31
Keep the gate locked in open state upon a second control command:
if this option is
enabled, the gate remains open permanently (
Y
=infinite) after receiving a second call from the
same user while the gate is opening or in open state (during the
X
+
W
+
Y
period). The gate will
close when a third call is received from the same user or a new call is received from a
different
user
. This function cannot be used with hidden caller ID.
Control mode 4
For single-gate automations that require triggers for opening and closing on different inputs.
OUT1=N.O. (normally open)
OUT2=N.O. (normally open)
X
= OUT1 pulse length (seconds) => for gate opening
Y
= keeping the gate open (seconds) => for keeping the gate locked in open state
Z
= OUT2 pulse length (seconds) => for gate closing
Starting a process of opening and closing by a single call, using caller identification. In idle state,
outputs OUT1 and OUT2 provide an open contact. Upon controlling the device, output OUT1
gives a closed contact for
X
seconds, then after
Y
seconds output OUT2 gives a closed contact
for
Z
seconds. You can use this control mode if the gate automation control board requires
triggers for opening and closing on two different inputs (a trigger pulse on an input opens the
gate, another trigger pulse on a different input closes the gate).
Keep the gate locked in open state upon a second control command:
if this option is
enabled, the gate remains open permanently (
Y
=infinite) after receiving a second call from the
same user while the gate is opening or in open state (during the
X
+
Y
period). The gate will close
when a third call is received from the same user or a new call is received from a
different user
.
This function cannot be used with hidden caller ID.
Control mode 5
For single-gate automations that require triggers for opening and closing on different inputs.
OUT1=N.O. (normally open)
OUT2=N.O. (normally open)
X
= OUT1 pulse length (seconds) => for gate opening
Z
= OUT2 pulse length (seconds) => for gate closing
Opening and closing by separate calls. In idle state, outputs OUT1 and OUT2 provide an open
contact. Output OUT1 gives a closed contact for
X
seconds upon the first call, and then upon the
second call from the same user, output OUT2 gives a closed contact for
Z
seconds. You can use
this control mode if the gate automation control board requires triggers for opening and closing
on the same input or on two different inputs. If opening and closing control is done on the same
input, outputs OUT1 and OUT2 should be connected in parallel to the input to be controlled.
This control mode cannot be used with hidden caller ID.